文献速递儿科影像骨肌USCT

超声筛查颅缝早闭的有效性:一项回顾性综述

Effectiveness of screening for craniosynostosis with ultrasound: a retrospective review.
PubMed 文献 · Pediatr Radiol · 2017-02-17

该回顾性研究纳入52例因头型异常行颅缝超声检查的患儿,以临床随访和/或头部CT为参考标准,评估超声筛查颅缝早闭的准确性。超声未发现颅缝早闭的45例均经随访体检和/或CT确认无异常 premature 闭合;超声发现颅缝早闭的7例均经CT或手术报告确认。超声敏感度100%(95%CI:56.1-100.0%),特异度100%(95%CI:90.2-100.0%),阴性预测值100%(95%CI:90.2-100.0%)。结论认为颅缝超声是排除头型异常患者颅缝早闭的可靠筛查工具。

要点

  • 颅缝超声阴性可可靠排除颅缝早闭,阴性预测值100%(95%CI:90.2-100.0%)。
  • 超声诊断颅缝早闭的敏感度100%(95%CI:56.1-100.0%),特异度100%(95%CI:90.2-100.0%)。
  • 对头型异常患儿,可考虑以颅缝超声作为筛查手段,减少CT电离辐射。

核心结论

  • 颅缝超声是排除头型异常患者颅缝早闭的可靠筛查工具。

研究设计与样本

  • 回顾性综述,纳入3年期间(2012年7月至2015年9月)所有颅缝超声检查,52例超声检查符合纳入标准;以临床随访和/或头部CT为参考标准。

关键影像表现/征象

  • 超声未显示骨性融合(无颅缝早闭)的45例,随访体检和/或CT均确认无异常 premature 颅缝闭合。
  • 超声显示颅缝早闭的7例,CT检查或手术报告均确认 premature 颅缝闭合。

诊断标准与关键数值

  • 超声诊断颅缝早闭的敏感度100%(95%CI:56.1-100.0%)。
  • 超声诊断颅缝早闭的特异度100%(95%CI:90.2-100.0%)。
  • 超声阴性预测值100%(95%CI:90.2-100.0%)。

临床应用与阅片要点

  • 对头型异常患儿,可考虑以颅缝超声作为筛查手段,以减少头部CT的电离辐射暴露。
  • 超声未发现颅缝早闭时,可依据其高阴性预测值排除颅缝早闭。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Minimizing the ionizing radiation dose to children is fundamental to pediatric radiology. The most widely accepted imaging examination for evaluating craniosynostosis is computed tomography (CT) of the head, an examination that involves ionizing radiation.

OBJECTIVE: To determine if sonography of the cranial sutures is an adequate screening examination for the diagnosis of craniosynostosis in patients with abnormal skull shape.

MATERIALS AND METHODS: A retrospective review of all cranial suture ultrasound (US) examinations performed during the course of a 3-year period (July 2012 - September 2015) was undertaken. Results were compared with clinical follow-up and/or head CT to evaluate the accuracy of this modality as a screening tool to determine the presence or absence of craniosynostosis. Fifty-two sonographic exams were adequate for inclusion.

RESULTS: Forty-five of the examinations did not reveal synostosis. In each of these instances, follow-up physical exam findings and/or CT imaging confirmed that no abnormal premature suture closure was present. US findings demonstrated synostosis in seven cases. CT exam or operative reports of these cases confirmed all seven findings of premature suture closure. Statistical analysis demonstrated a sensitivity of 100% (95% confidence interval [CI]: 56.1-100.0%), a specificity of 100% (95% CI: 90.2-100.0%), and a negative predictive value of 100% (95% CI: 90.2-100.0%).

CONCLUSION: Cranial US is a reliable screening tool to rule out craniosynostosis in patients with abnormal head shape.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Hall KM, Besachio DA, Moore MD, et al. Effectiveness of screening for craniosynostosis with ultrasound: a retrospective review. Pediatr Radiol. 2017. PMID: 28213626. doi:10.1007/s00247-017-3793-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。