疑似外周动脉疾病CT血管成像:透析与非透析患者下肢对比增强比较
回顾性分析287例因疑似外周动脉疾病行下肢CTA的患者,分为非透析依赖组(151例)、透析依赖且CTA后24小时内透析组(70例)和透析依赖且CTA前24小时内透析组(66例)。透析后24小时内行CTA组腘动脉CT值中位数最低(373 HU vs 非透析组429 HU和透析前组418 HU),膝降动脉显示评分也显著低于非透析组(p=0.02)和透析前组(p=0.04)。提示透析后随时间推移动脉强化减弱,可能因血管内容量增加;透析后24小时内行CTA图像质量优于透析前24小时内。
要点
- 透析后24小时内行下肢CTA的腘动脉CT值中位数最低(373 HU),低于非透析组(429 HU)和透析前组(418 HU)。
- 透析后24小时内CTA的膝降动脉显示评分显著低于非透析组(p=0.02)和透析前组(p=0.04)。
- 疑似外周动脉疾病的透析依赖患者,透析后24小时内行CTA下肢动脉图像质量优于透析前24小时内。
核心结论
- 下肢CTA中动脉强化随透析后时间推移而减弱,可能因血管内容量增加;透析后24小时内行CTA的下肢图像质量优于透析前24小时内行CTA。
研究设计与样本
- 回顾性研究,纳入287例连续因疑似外周动脉疾病行下肢CTA的患者,使用64排MDCT扫描仪,分为非透析依赖组(n=151)、透析依赖且CTA后24小时内透析组(n=70)和透析依赖且CTA前24小时内透析组(n=66)。
关键影像表现/征象
- 比较所有CTA图像上髌骨水平腘动脉的CT值。
- 由一名心脏科医生和一名放射科技师目测评估膝降动脉(DGA)显示情况并赋予显示评分。
诊断标准与关键数值
- 腘动脉CT值中位数:非透析依赖组429 HU,透析后24小时内透析组373 HU,透析前24小时内透析组418 HU,透析后组最低。
- 膝降动脉显示评分:透析后24小时内透析组显著低于非透析依赖组(p=0.02)和透析前24小时内透析组(p=0.04)。
临床应用与阅片要点
- 对于透析依赖的疑似外周动脉疾病患者,透析后24小时内行下肢CTA较透析前24小时内可获得更高的动脉强化和膝降动脉显示质量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The objective of our study was to compare contrast enhancement on CT angiography (CTA) images of the lower extremity in patients with suspected peripheral artery disease who did not undergo hemodialysis (HD) and patients who were scanned before or after HD.
MATERIALS AND METHODS: We divided 287 consecutive patients who underwent CTA of the lower extremity on a 64-MDCT scanner into three groups: group 1 patients (n = 151) were not dependent on HD, group 2 patients (n = 70) were dependent on HD and underwent HD less than 24 hours after CTA, and group 3 (n = 66) were dependent on HD and underwent HD less than 24 hours before CTA. We then compared the CT number in the popliteal artery at the level of the patella on all CTA images. A cardiologist and a radiology technologist visually evaluated the depiction of the descending genicular artery (DGA) on the CTA images and assigned a visualization score.
RESULTS: The median CT number was lowest in group 2 patients (373 HU vs 429 [group 1] and 418 [group 3] HU). The score for visualization of the DGA was significantly lower in group 2 than in group 1 (p = 0.02) and group 3 (p = 0.04).
CONCLUSION: At CTA, arterial enhancement decreases with the passage of time after HD likely because of the increase in intravascular volume. CTA that is performed within 24 hours after HD generates higher-quality images of the lower extremities than CTA that is performed within 24 hours before HD.
引用
- Masuda T, Funama Y, Nakaura T, et al. CT Angiography of Suspected Peripheral Artery Disease: Comparison of Contrast Enhancement in the Lower Extremities of Patients Undergoing and Those Not Undergoing Hemodialysis. AJR Am J Roentgenol. 2017. PMID: 28177650. doi:10.2214/AJR.16.16810
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。