文献速递外周血管技术与安全US

年轻健康人静息与运动时颈总动脉直径、血流速度及波强度反应的重测信度研究

Common Carotid Artery Diameter, Blood Flow Velocity and Wave Intensity Responses at Rest and during Exercise in Young Healthy Humans: A Reproducibility Study.
PubMed 文献 · Ultrasound Med Biol · 2017-02-23

研究纳入12名健康年轻受试者,在静息和轻度骑行时用超声记录颈总动脉直径与血流速度,评估无创波强度分析的可重复性。直径变量重测信度高于速度变量(ICC 0.79 vs 0.73),波速信度一般(ICC 0.6),波强度能量变量信度高于对应峰值(ICC 0.78 vs 0.74),多数变量运动时ICC更高、CV更低。作者结论为无创波强度分析在静息和运动时均可靠。

要点

  • 颈总动脉直径变量重测信度高于速度变量(ICC 0.79 vs 0.73,CV 5% vs 9%)。
  • 波强度能量变量重测信度高于对应峰值(ICC 0.78 vs 0.74,CV 16% vs 18%)。
  • 多数变量在运动时ICC更高、CV更低,波速信度一般(ICC 0.6,CV 16%)。

核心结论

  • 无创波强度分析在静息和运动时均可靠。

研究设计与样本

  • 重测信度研究,纳入12名健康年轻受试者,在静息和轻度骑行时用超声记录颈总动脉直径与血流速度,评估峰值直径、直径变化、峰值速度、速度变化、时间导数、无创波速和波强度参数的可重复性。

诊断标准与关键数值

  • 直径变量ICC 0.79、CV 5%,速度变量ICC 0.73、CV 9%。
  • 波速ICC 0.6、CV 16%。
  • 波强度能量变量ICC 0.78、CV 16%,对应峰值ICC 0.74、CV 18%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The aim of this study was to assess the reproducibility of non-invasive, ultrasound-derived wave intensity (WI) in humans at the common carotid artery. Common carotid artery diameter and blood velocity of 12 healthy young participants were recorded at rest and during mild cycling, to assess peak diameter, change in diameter, peak velocity, change in velocity, time derivatives, non-invasive wave speed and WI. Diameter, velocity and WI parameters were fairly reproducible. Diameter variables exhibited higher reproducibility than corresponding velocity variables (intra-class correlation coefficient [ICC] = 0.79 vs. 0.73) and lower dispersion (coefficient of variation [CV] = 5% vs. 9%). Wave speed had fair reproducibility (ICC = 0.6, CV = 16%). WI energy variables exhibited higher reproducibility than corresponding peaks (ICC = 0.78 vs. 0.74) and lower dispersion (CV = 16% vs. 18%). The majority of variables had higher ICCs and lower CVs during exercise. We conclude that non-invasive WI analysis is reliable both at rest and during exercise.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Pomella N, Wilhelm EN, Kolyva C, et al. Common Carotid Artery Diameter, Blood Flow Velocity and Wave Intensity Responses at Rest and during Exercise in Young Healthy Humans: A Reproducibility Study. Ultrasound Med Biol. 2017. PMID: 28237637. doi:10.1016/j.ultrasmedbio.2016.12.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。