非增强3-T磁共振成像与1.5-T磁共振关节造影在股骨髋臼撞击综合征中的诊断效能比较
研究纳入50例临床怀疑股骨髋臼撞击综合征的患者,同期行1.5-T磁共振关节造影、3-T非增强磁共振成像及关节镜检查。3-T非增强MRI诊断盂唇软骨移行区撕裂的敏感度97.7%、特异度100%、准确率98%;1.5-T MRA敏感度100%、特异度85.7%、准确率98%。作者认为3-T非增强MRI可替代MRA作为评估髋关节内部损伤的主力技术。
要点
- 3-T非增强MRI诊断盂唇软骨移行区撕裂敏感度97.7%、特异度100%、准确率98%。
- 1.5-T MRA诊断盂唇撕裂敏感度100%、特异度85.7%、准确率98%,出现1例假阳性。
- 关节镜与MRI对髋臼软骨损伤程度的一致率仅半数患者,股骨侧为76%。
核心结论
- 3-T非增强MRI诊断盂唇软骨移行区撕裂的敏感度97.7%、特异度100%、准确率98%,与1.5-T MRA准确率相同(98%),作者认为3-T非增强MRI可替代MRA作为评估髋关节内部损伤的主力技术。
研究设计与样本
- 50例临床怀疑股骨髋臼撞击综合征的患者(男30例、女20例,平均年龄42.5岁)在同一髋关节行1.5-T磁共振关节造影、3-T非增强MRI及关节镜检查;3-T非增强MRI方案包含优化的高分辨率质子密度自旋回波脉冲序列;以关节镜为参考标准。
诊断标准与关键数值
- 3-T非增强MRI诊断盂唇软骨移行区撕裂:敏感度97.7%、特异度100%、阳性预测值100%、阴性预测值87.5%、准确率98%(43处关节镜证实的撕裂中检出42处)。1.5-T MRA诊断盂唇撕裂:敏感度100%、特异度85.7%、阳性预测值97.7%、阴性预测值100%、准确率98%(诊断44处撕裂,含1例假阳性)。
临床应用与阅片要点
- 作者认为3-T非增强MRI可替代MRA作为评估髋关节内部损伤的主力技术,MRA则保留用于临床高度怀疑股骨髋臼撞击综合征但3-T非增强MRI表现正常的年轻成人。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The aim of this study was to evaluate the diagnostic accuracy of 3-T non-contrast MRI versus 1.5-T MRA for assessing labrum and articular cartilage lesions in patients with clinical suspicion of femoro-acetabular impingement (FAI).
SUBJECTS AND METHODS: Fifty patients (thirty men and twenty women, mean age 42.5 years) underwent 1.5-T MRA, 3-T MRI and arthroscopy on the same hip. An optimized high-resolution proton density spin echo pulse sequence was included in the 3-T non-contrast MRI protocol.
RESULTS: The 3-T non-contrast MRI identified forty-two of the forty-three arthroscopically proven tears at the labral-chondral transitional zone (sensitivity, 97.7%; specificity, 100%; positive predictive value (PPV), 100%; negative predictive value (NPV), 87.5%; accuracy 98%). With 1.5-T MRA, forty-four tears were diagnosed. However, there was one false positive (sensitivity, 100%; specificity, 85.7%; PPV, 97.7%; NPV, 100%; accuracy 98%). Agreement between arthroscopy and MRI, whether 3-T non-contrast MRI or 1.5-T MRA, as to the degree of chondral lesion in the acetabulum was reached in half of the patients and in the femur in 76% of patients.
CONCLUSION: Non-invasive assessment of the hip is possible with 3-T MR magnet. 3-T non-contrast MRI could replace MRA as the workhorse technique for assessing hip internal damage. MRA would then be reserved for young adults with a strong clinical suspicion of FAI but normal findings on 3-T non-contrast MRI. When compared with 1.5-T MRA, optimized sequences with 3-T non-contrast MRI help in detecting normal variants and in diagnosing articular cartilage lesions.
引用
- Crespo-Rodríguez AM, De Lucas-Villarrubia JC, Pastrana-Ledesma M, et al. The diagnostic performance of non-contrast 3-Tesla magnetic resonance imaging (3-T MRI) versus 1.5-Tesla magnetic resonance arthrography (1.5-T MRA) in femoro-acetabular impingement. Eur J Radiol. 2016. PMID: 28189195. doi:10.1016/j.ejrad.2016.12.031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。