文献速递神经骨肌MR

三维T2-SPACE与T2-FSE在颈椎MRI解剖评估中的诊断质量比较

Diagnostic Quality of 3D T2-SPACE Compared with T2-FSE in the Evaluation of Cervical Spine MRI Anatomy.
PubMed 文献 · AJNR Am J Neuroradiol · 2017-02-02

本研究纳入2014年9月至2015年2月间因神经根病或脊髓病行颈椎MR检查的45例成人患者,比较T2-SPACE与T2-FSE序列对12个解剖结构的显示质量。两位盲法放射科医生独立评分,结果显示椎间盘信号、神经孔、黄韧带、腹侧及背侧神经根袖的平均显示评分T2-SPACE均高于T2-FSE(P < .001),且T2-SPACE的脑脊液搏动伪影更轻(P < .001)。结论认为T2-SPACE在颈椎解剖结构评估中可能等同或优于T2-FSE。

要点

  • T2-SPACE对椎间盘信号、神经孔、黄韧带、腹侧及背侧神经根袖的显示评分均高于T2-FSE(P < .001)。
  • T2-SPACE的脑脊液搏动伪影程度低于T2-FSE(P < .001)。
  • 两序列的观察者间一致性均为轻度至中等(κ范围:T2-SPACE -0.02~0.20,T2-FSE -0.02~0.30)。

核心结论

  • T2-SPACE在颈椎解剖结构评估中可能等同或优于T2-FSE,且脑脊液搏动伪影更轻。

研究设计与样本

  • 回顾性纳入2014年9月至2015年2月间因神经根病或脊髓病行颈椎MR检查并同时采集T2-SPACE与T2-FSE序列的45例成人患者(平均年龄57岁,40%男性),由两位盲法亚专科放射科医生独立评分,参考标准为5分法解剖结构显示评分与4分法脑脊液搏动伪影评分。

关键影像表现/征象

  • 椎间盘信号、神经孔、黄韧带、腹侧神经根袖及背侧神经根袖的平均显示评分T2-SPACE高于T2-FSE(两位阅片者均P < .001)。
  • 其余结构的平均评分或组间无统计学差异,或某一序列的优越性在两位阅片者间不一致。
  • T2-SPACE的脑脊液流动伪影程度低于T2-FSE(P < .001)。

诊断标准与关键数值

  • 解剖结构显示采用5分法评分,脑脊液搏动伪影采用4分法评分。
  • 椎间盘信号、神经孔、黄韧带、腹侧神经根袖、背侧神经根袖的平均显示评分T2-SPACE高于T2-FSE(P < .001)。
  • 观察者间一致性κ值:T2-SPACE为-0.02~0.20,T2-FSE为-0.02~0.30,均为轻度至中等一致。

临床应用与阅片要点

  • 在颈椎MR解剖结构评估中,T2-SPACE对椎间盘信号、神经孔、黄韧带及神经根袖的显示可能等同或优于T2-FSE。
  • T2-SPACE的脑脊液搏动伪影程度低于T2-FSE,可能有助于减少伪影对图像判读的干扰。
  • 两序列的观察者间一致性均为轻度至中等,阅片时需注意结构判读的可重复性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Spinal anatomy has been variably investigated using 3D MRI. We aimed to compare the diagnostic quality of T2 sampling perfection with application-optimized contrasts by using flip angle evolution (SPACE) with T2-FSE sequences for visualization of cervical spine anatomy. We predicted that T2-SPACE will be equivalent or superior to T2-FSE for visibility of anatomic structures.

MATERIALS AND METHODS: Adult patients undergoing cervical spine MR imaging with both T2-SPACE and T2-FSE sequences for radiculopathy or myelopathy between September 2014 and February 2015 were included. Two blinded subspecialty-trained radiologists independently assessed the visibility of 12 anatomic structures by using a 5-point scale and assessed CSF pulsation artifact by using a 4-point scale. Sagittal images and 6 axial levels from C2-T1 on T2-FSE were reviewed; 2 weeks later and after randomization, T2-SPACE was evaluated. Diagnostic quality for each structure and CSF pulsation artifact visibility on both sequences were compared by using a paired t test. Interobserver agreement was calculated (κ).

RESULTS: Forty-five patients were included (mean age, 57 years; 40% male). The average visibility scores for intervertebral disc signal, neural foramina, ligamentum flavum, ventral rootlets, and dorsal rootlets were higher for T2-SPACE compared with T2-FSE for both reviewers (P < .001). Average scores for remaining structures were either not statistically different or the superiority of one sequence was discordant between reviewers. T2-SPACE showed less degree of CSF flow artifact (P < .001). Interobserver variability ranged between -0.02-0.20 for T2-SPACE and -0.02-0.30 for T2-FSE (slight to fair agreement).

CONCLUSIONS: T2-SPACE may be equivalent or superior to T2-FSE for the evaluation of cervical spine anatomic structures, and T2-SPACE shows a lower degree of CSF pulsation artifact.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Chokshi FH, Sadigh G, Carpenter W, et al. Diagnostic Quality of 3D T2-SPACE Compared with T2-FSE in the Evaluation of Cervical Spine MRI Anatomy. AJNR Am J Neuroradiol. 2017. PMID: 28154126. doi:10.3174/ajnr.A5080

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。