文献速递骨肌PETCTMR

肩关节喙肱韧带区或下关节囊局灶性摄取在18F-FDG PET/CT上与粘连性关节囊炎相关

Focal uptake at the rotator interval or inferior capsule of shoulder on 18F-FDG PET/CT is associated with adhesive capsulitis.
PubMed 文献 · Skeletal Radiol · 2017-02-04

15例PET阳性者中9例临床诊断为粘连性关节囊炎(AC),PET诊断AC的敏感度56%、特异度87%,阳性似然比6.3(95%CI 2.8-14.6)。结论认为RI或IC摄取增高中度增加AC的可能性。

要点

  • 肩关节RI或IC局灶性FDG摄取(「PET阳性」)在连续PET/CT中患病率仅0.53%。
  • PET阳性诊断AC的敏感度56%、特异度87%、阳性似然比6.3(95%CI 2.8-14.6)。
  • 阅片时发现RI或IC局灶性摄取应提示AC可能,但敏感度有限。

核心结论

  • RI或IC 18F-FDG摄取增高使AC的可能性中度增加,阳性似然比6.3(95%CI 2.8-14.6)。

研究设计与样本

  • 回顾性分析三组人群:组1为1137例连续18F-FDG PET/CT用于确定RI或IC局灶性摄取的患病率;组2为10年间361例肩关节PET/CT与MRI间隔45天内完成者用于富集研究组;组3为与组1、组2同时期随机选取的109例用于生成对照组;研究组为三组中15例PET阳性者,由两名骨肌放射科医生共识评估,AC参考标准为疼痛医学医生复习病历后的临床诊断。

关键影像表现/征象

  • RI或IC局灶性FDG摄取(「PET阳性」)在连续PET/CT中的患病率为0.53%。

诊断标准与关键数值

  • PET诊断AC的敏感度56%、特异度87%,阳性似然比6.3(95%CI 2.8-14.6)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine if focal increased uptake at the rotator interval (RI) and/or inferior capsule (IC) on18F-FDG PET/CT ("positive PET") predicts the presence of adhesive capsulitis (AC).

MATERIALS AND METHODS: Three populations were retrospectively examined. Group 1 included 1,137 consecutive 18F-FDG PET/CT studies and was used to determine the prevalence of focal uptake at the RI or IC. Group 2 included 361 cases from a 10-year period with 18F-FDG PET/CT and MRI of shoulder performed within 45 days of each other and was used to enrich the study group. Group 3 included 109 randomly selected patients from the same time frame as groups 1 and 2 and was used to generate the control group. The study group consisted of 15 cases from the three groups, which had positive PET findings. PET/CT images were assessed in consensus by two musculoskeletal radiologists. The reference standard for a diagnosis of AC was clinical and was made by review of the medical record by a pain medicine physician.

RESULTS: The prevalence of focal activity at either the RI or IC ("positive PET") was 0.53%. Nine patients had a clinical diagnosis of AC and 15 patients had a positive PET. The sensitivity and specificity of PET for detection of AC was 56% and 87%, respectively. PET/CT had a positive likelihood ratio for AC of 6.3 (95% CI: 2.8-14.6).

CONCLUSIONS: Increased uptake at the RI or IC on PET/CT confers a moderate increase in the likelihood of AC.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Sridharan R, Engle MP, Garg N, et al. Focal uptake at the rotator interval or inferior capsule of shoulder on 18F-FDG PET/CT is associated with adhesive capsulitis. Skeletal Radiol. 2017. PMID: 28161721. doi:10.1007/s00256-017-2587-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。