基于信号强度加权平均的骨骼肌无偏纤维束追踪:新方法开发及与其他校正技术的比较
研究在3T磁共振上对10名志愿者右小腿和大腿行STEAM-DTI扫描,探讨随机图像伪影来源并开发基于信号强度加权平均(WMSI)的自动后处理校正方法,与迭代重加权线性最小二乘和iRESTORE比较。WMSI校正后小腿和大腿纤维束指标(数量、长度、体积)在感兴趣区和掩膜分析中均显著改善(P < 0.05),肌肉勾画和伪影负荷也显著改善(P < 0.05),且WMSI比iRESTORE更快。
要点
- STEAM-DTI中随机伪影影响所有志愿者数据集,随意肌收缩时伪影负担从23.1%增至77.5%,离体标本无伪影。
- WMSI校正后小腿和大腿纤维束数量、长度、体积均显著改善(P < 0.05),肌肉勾画和伪影负荷也显著改善(P < 0.05)。
- WMSI与迭代重加权线性最小二乘及iRESTORE结果等效,但WMSI比iRESTORE更快。
核心结论
- 信号强度加权平均校正显著改善基于STEAM的定量DTI分析和下肢肌肉纤维束追踪,为肌肉骨骼应用提供稳健工具。
研究设计与样本
- 前瞻性方法学研究,10名志愿者右小腿和大腿在3T磁共振上行STEAM-DTI序列,并纳入离体人尸体小腿和火鸡腿以相同DTI参数扫描;参考标准为不同平均次数和伪影校正条件下的DTI及纤维束追踪指标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to investigate the origin of random image artifacts in stimulated echo acquisition mode diffusion tensor imaging (STEAM-DTI), assess the role of averaging, develop an automated artifact postprocessing correction method using weighted mean of signal intensities (WMSIs), and compare it with other correction techniques.
MATERIALS AND METHODS: Institutional review board approval and written informed consent were obtained. The right calf and thigh of 10 volunteers were scanned on a 3 T magnetic resonance imaging scanner using a STEAM-DTI sequence.Artifacts (ie, signal loss) in STEAM-based DTI, presumably caused by involuntary muscle contractions, were investigated in volunteers and ex vivo (ie, human cadaver calf and turkey leg using the same DTI parameters as for the volunteers). An automated postprocessing artifact correction method based on the WMSI was developed and compared with previous approaches (ie, iteratively reweighted linear least squares and informed robust estimation of tensors by outlier rejection [iRESTORE]). Diffusion tensor imaging and fiber tracking metrics, using different averages and artifact corrections, were compared for region of interest- and mask-based analyses. One-way repeated measures analysis of variance with Greenhouse-Geisser correction and Bonferroni post hoc tests were used to evaluate differences among all tested conditions. Qualitative assessment (ie, images quality) for native and corrected images was performed using the paired t test.
RESULTS: Randomly localized and shaped artifacts affected all volunteer data sets. Artifact burden during voluntary muscle contractions increased on average from 23.1% to 77.5% but were absent ex vivo. Diffusion tensor imaging metrics (mean diffusivity, fractional anisotropy, radial diffusivity, and axial diffusivity) had a heterogeneous behavior, but in the range reported by literature. Fiber track metrics (number, length, and volume) significantly improved in both calves and thighs after artifact correction in region of interest- and mask-based analyses (P < 0.05 each). Iteratively reweighted linear least squares and iRESTORE showed equivalent results, but WMSI was faster than iRESTORE. Muscle delineation and artifact load significantly improved after correction (P < 0.05 each).
CONCLUSIONS: Weighted mean of signal intensity correction significantly improved STEAM-based quantitative DTI analyses and fiber tracking of lower-limb muscles, providing a robust tool for musculoskeletal applications.
引用
- Giraudo C, Motyka S, Weber M, et al. Weighted Mean of Signal Intensity for Unbiased Fiber Tracking of Skeletal Muscles: Development of a New Method and Comparison With Other Correction Techniques. Invest Radiol. 2017. PMID: 28240621. doi:10.1097/RLI.0000000000000364
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。