磁敏感加权磁共振成像评估脊柱Modic改变的硬化
这项前瞻性研究纳入54例患者,评估磁敏感加权磁共振成像(SWMR)鉴别脊柱Modic改变中硬化与非硬化的诊断性能,以CT和X线为参考标准。SWMR上硬化与非硬化Modic改变的信号测量差异有统计学意义(p<0.01),鉴别敏感度100%、特异度95%;而T1/T2加权MR组合检出硬化的敏感度仅20%。结论认为SWMR能可靠检出Modic改变中的硬化,准确率高于标准脊柱MR序列。
要点
- SWMR鉴别硬化与非硬化Modic改变的敏感度100%、特异度95%。
- T1/T2加权MR组合检出硬化的敏感度仅20%,显著低于SWMR。
- SWMR上硬化与非硬化Modic改变信号测量差异有统计学意义(p<0.01)。
核心结论
- SWMR能可靠检出Modic改变中的硬化,以X线和CT为参考标准,准确率高于标准脊柱MR序列。
研究设计与样本
- 前瞻性研究,经机构伦理审查委员会预先批准,所有受试者签署书面知情同意;54例患者行颈椎(n=21)和/或腰椎(n=34)SWMR及标准T1/T2 MR,21例为对照;18例行CT,其余患者有X线片;T1/T2 MR上识别67个Modic改变,以CT和X线为参考标准。
关键影像表现/征象
- SWMR上硬化与非硬化Modic改变的信号测量差异有统计学意义(p<0.01)。
- T1加权和T2加权MR上硬化与非硬化Modic改变信号测量差异无统计学意义(p>0.05)。
诊断标准与关键数值
- SWMR以信号强度测量将Modic改变分为硬化与非硬化,鉴别敏感度100%、特异度95%。
- T1/T2加权MR组合检出硬化的敏感度20%,显著低于SWMR。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the diagnostic performance of susceptibility-weighted magnetic resonance imaging (SWMR) for the differentiation of sclerotic and non-sclerotic Modic changes (MC) of the spine compared to computed tomography (CT) and radiographs.
MATERIALS AND METHODS: The Institutional Ethics-Review-Board approved this prospective study in advance. Written consent was obtained from all subjects. SWMR and standard T1/T2 MR of the cervical (n=21) and/or lumbar spine (n=34) were performed in 54 patients. 21 patients served as control. 18 patients were evaluated with CT; in all other patients radiographs were available. 67 Modic changes were identified on T1/T2 MR. On SWMR changes were classified as sclerotic and non-sclerotic based on signal intensity measurements. The sensitivity and specificity of SWMR and T1/T2 MR for differentiating between sclerotic and non-sclerotic Modic changes were determined with CT and radiographs as reference standard.
RESULTS: On SWMR, signal measurements between sclerotic and non-sclerotic Modic changes differed significantly (p<0.01). On T1- and T2-weighted MR no significant difference (p>0.05) was measured. On SWMR, a reliable differentiation between sclerotic and non-sclerotic Modic changes could be achieved, with a sensitivity of 100% and specificity of 95%. In contrast, the combination of T1-/T2-weighted MR yielded a significantly lower sensitivity to detect sclerosis (20%).
CONCLUSION: SWMR allows a reliable detection of sclerosis in Modic changes with a higher accuracy compared to standard spine MR sequences, using radiographs and CT as reference standard.
引用
- Böker SM, Bender YY, Adams LC, et al. Evaluation of sclerosis in Modic changes of the spine using susceptibility-weighted magnetic resonance imaging. Eur J Radiol. 2016. PMID: 28189200. doi:10.1016/j.ejrad.2016.12.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。