文献速递骨肌MR

肩关节MR关节造影:各向同性三维中间加权快速自旋回波与混合梯度回波T1加权序列的评估

MR arthrography of the shoulder: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences.
PubMed 文献 · Radiol Med · 2017-02-15

回顾性纳入2011年9月至2014年10月间102例接受1.5 Tesla肩关节MR关节造影的患者,比较二维快速自旋回波(2D)、三维中间加权快速自旋回波(IW-3D)与三维混合双回波稳态T1加权(Hy-3D)序列以手术为参考标准评估肩袖和盂唇病变的诊断准确性。三种序列诊断准确性差异无统计学意义,观察者间一致性均很好。

要点

  • IW-3D与Hy-3D序列评估肩袖和盂唇病变的准确性并不显著高于2D序列。
  • 2D、Hy-3D、IW-3D评估肩袖及盂唇病变的准确性分别为95.1%、92.1%、91.2%与93.1%、93.1%、94.1%。
  • 各数据集观察者间一致性均很好,2D k=0.86、Hy-3D k=0.81、IW-3D k=0.83。

核心结论

  • IW-3D与Hy-3D图像评估肩袖和盂唇病变的准确性并不显著高于2D序列。

研究设计与样本

  • 回顾性研究,纳入2011年9月至2014年10月共102例接受1.5 Tesla肩关节MR关节造影(含常规2D-FSE、IW-3D和Hy-3D图像)的患者,以手术为参考标准,MR关节造影与手术的平均间隔为21天(范围2-70天)。

诊断标准与关键数值

  • 以手术为参考标准,2D、Hy-3D与IW-3D评估肩袖病变和盂唇病变的准确性分别为95.1%、92.1%、91.2%与93.1%、93.1%、94.1%;2D与IW-3D的AUC差值范围为0.002(p=0.98)至0.014(p=0.82),2D与Hy-3D为0.002(p=0.98)至0.034(p=0.08),Hy-3D与IW-3D为0.010(p=0.82)至0.032(p=0.09)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the diagnostic accuracy of three-dimensional (3D) fast spin echo (FSE) intermediate-weighed (IW-3D) and 3D hybrid double-echo steady-state T1-weighted sequences (Hy-3D) and two-dimensional (FSE) images (2D) at shoulder MR arthrography (MRA).

MATERIALS AND METHODS: Institutional review board approval was obtained and informed consent was waived for this retrospective study. From September 2011 to October 2014, 102 patients who had undergone 1.5 Tesla MRA of the shoulder, including conventional 2D-FSE and IW-3D and Hy-3D images were included in our study. The mean interval between MRA and surgery was 21 days (range 2-70 days). MR images were retrospectively and independently reviewed by two experienced radiologists blinded to the clinical and surgical data. Supraspinatus tendon (SST), infraspinatus tendon (IST) and subscapularis tendon (SCT) tears, as well as antero-inferior, superior and posterior labral lesions were assessed, using surgery as the reference standard. Each reader's performance in assessing rotator cuff and labrum abnormalities was evaluated using the area under the receiver operating characteristic curve (AUC) and 95% confidence intervals (CIs). The difference was evaluated using a univariate z test. The sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV) and accuracy (Acc) for all types of rotator cuff tears and labral lesions were calculated. A value of p < 0.05 was considered statistically significant. Inter-observer agreement was calculated using kappa statistics.

RESULTS: The difference of diagnostic accuracy achieved was not significant (p > 0.05). In particular, differences in AUC values ranged from 0.002 (p = 0.98) to 0.014 (p = 0.82) as regards the comparison between 2D and IW-3D images, from 0.002 (p = 0.98) to 0.034 (p = 0.08) concerning the comparison between 2D and Hy-3D images and from 0.010 (p = 0.82) to 0.032 (p = 0.09) when comparing Hy-3D to IW-3D images. Accuracy values in evaluating RC lesions and labral lesions were 95.1, 92.1, 91.2, 93.1, 93.1 and 94.1% by reading 2D, Hy-3D and IW-3D images, respectively. The difference of diagnostic accuracy achieved using the datasets analyzed was not significant (p > 0.05). Inter-observer agreement was very good for each of the datasets that were evaluated, with near-perfect agreement for 2D dataset (k = 0.86), Hy-3D (k = 0.81) and IW-3D (k = 0.83).

CONCLUSIONS: The accuracy of IW-3D and Hy-3D images was not significantly higher than the 2D sequences in evaluating RC and labral lesions.