文献速递头颈CT

计算机断层扫描定位甲状旁腺腺瘤的诊断效能:系统评价与Meta分析

Diagnostic performance of computed tomography for parathyroid adenoma localization; a systematic review and meta-analysis.
PubMed 文献 · Eur J Radiol · 2017-01-05

该系统评价与Meta分析纳入34项研究共2563例非家族性原发性甲状旁腺功能亢进症患者,评估CT术前定位病理甲状旁腺的敏感度和阳性预测值。CT总体汇总敏感度在定位至正确象限为73%(95%CI:69-78%),侧向定位为81%(95%CI:75-87%)。亚组分析显示采用两期对比剂方案在可接受的诊断效能与限制辐射暴露之间似乎取得较好平衡。

要点

  • CT定位病理甲状旁腺至正确象限的汇总敏感度为73%(95%CI:69-78%)。
  • CT侧向定位至正确侧的汇总敏感度为81%(95%CI:75-87%)。
  • 对比剂期数增加可提升敏感度:两期较单期提高,三期进一步轻度提高。

核心结论

  • CT在定位原发性甲状旁腺功能亢进症患者的病理甲状旁腺方面表现良好。
  • 采用两期对比剂方案似乎在可接受的诊断效能与限制辐射暴露之间取得较好平衡。

研究设计与样本

  • 系统评价与Meta分析,检索Embase、PubMed和Cochrane Library数据库2000年1月1日至2016年3月31日发表的文献。
  • 纳入34项研究,共2563例经生化诊断为原发性甲状旁腺功能亢进症、接受CT定位及手术切除的非家族性患者。
  • 采用随机效应模型汇总敏感度和阳性预测值,并通过亚组分析探讨可能影响诊断效能的因素。

诊断标准与关键数值

  • CT定位病理甲状旁腺至正确象限的总体汇总敏感度为73%(95%CI:69-78%)。
  • CT侧向定位至正确侧的汇总敏感度为81%(95%CI:75-87%)。
  • 单期对比剂方案的汇总敏感度为71%(95%CI:61-80%),增加第二期对比剂后敏感度升至76%(95%CI:71-87%),增加第三期后敏感度为80%(95%CI:74-86%)。

临床应用与阅片要点

  • 术前CT可用于原发性甲状旁腺功能亢进症患者的病理甲状旁腺定位,侧向定位敏感度高于象限定位。
  • 两期对比剂CT方案似乎可在保持可接受诊断效能的同时限制辐射暴露。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To perform a systematic review and meta-analysis of the sensitivity and positive predictive value (PPV) of CT for preoperative parathyroid localization in patients with primary hyperparathyroidism (pHPT), and subsequently compare the different protocols and their performance in different patient groups.

MATERIALS AND METHODS: We performed a search of the Embase, Pubmed and Cochrane Library databases to identify studies published between January 1, 2000 and March 31, 2016 investigating the diagnostic value of CT for parathyroid localization in patients with biochemical diagnosis of pHPT. Performance of CT was expressed in sensitivity and PPV with pooled proportion using a random-effects model. Factors that could have affected the diagnostic performance were investigated by subgroup analysis.

RESULTS: Thirty-four studies evaluating a total of 2563 patients with non-familial pHPT who underwent CT localization and surgical resection were included. Overall pooled sensitivity of CT for localization of the pathological parathyroid(s) to the correct quadrant was 73% (95% CI: 69-78%), which increased to 81% (95% CI: 75-87%) for lateralization to the correct side. Subgroup analysis based on the number of contrast phases showed that adding a second contrast phase raises sensitivity from 71% (95% CI: 61-80%) to 76% (95% CI: 71-87%), and that adding a third phase resulted in a more modest additional increase in performance with a sensitivity of 80% (95% CI: 74-86%).

CONCLUSION: CT performs well in localizing pathological glands in patients with pHPT. A protocol with two contrast phases seems to offer a good balance of acceptable performance with limitation of radiation exposure.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Kluijfhout WP, Pasternak JD, Beninato T, et al. Diagnostic performance of computed tomography for parathyroid adenoma localization; a systematic review and meta-analysis. Eur J Radiol. 2017. PMID: 28189196. doi:10.1016/j.ejrad.2017.01.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。