研究纳入118例乳腺影像报告和数据系统3类、紧邻皮肤或乳晕的肿块,在超声引导真空辅助活检时于探头插入点上方插入脊髓针。肿块最浅部分至皮肤下表面的平均距离为1.3±0.4 mm,平均操作时间13.5±4.2 min,100%病例实现完全切除,无患者发生皮肤撕裂等严重不良事件。

要点

  • 对紧邻皮肤或乳晕的BI-RADS 3类肿块,活检时于探头插入点上方插入脊髓针可预防皮肤撕裂。
  • 本组118例均实现完全切除,无皮肤撕裂等严重不良事件发生。
  • 肿块最浅部分至皮肤下表面平均距离仅1.3±0.4 mm,操作需注意保护皮肤。

核心结论

  • 这是首项预防真空辅助乳腺活检中皮肤撕裂的研究,所描述方法简单、安全且患者耐受良好。

研究设计与样本

  • 研究纳入118例患者共118个BI-RADS 3类、紧邻皮肤或乳晕的乳腺肿块,采用mammotome系统于探头插入点上方插入脊髓针后切除。

关键影像表现/征象

  • 肿块最浅部分至覆盖皮肤下表面的平均距离为1.3±0.4 mm。
  • 平均操作时间为13.5±4.2 min。
  • 100%的病例实现完全切除。
  • 所有患者对操作耐受良好,无患者发生皮肤撕裂等严重不良事件。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To describe a new technique to prevent skin laceration during ultrasound-guided vacuum-assisted breast biopsy with the insertion of a spinal needle between the mass and the skin.

METHODS: The study includes 118 patients with 118 breast imaging-reporting and data system Category 3 masses located very close to the skin or areola, which were excised using the mammotome system with a spinal needle inserted just above the site of insertion of the probe.

RESULTS: The mean distance between the most superficial portion of the mass to the under surface of the overlying skin was 1.3 ± 0.4 mm. The average procedure time was 13.5 ± 4.2 min. A complete excision was achieved in 100% of the cases, and the procedure was well tolerated by all the patients. No patient experienced serious adverse events such as a skin laceration.

CONCLUSION: This is the first study to prevent skin laceration during vacuum assisted breast biopsy. Advances in knowledge: The method described in this study is simple, safe and well tolerated by patients.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Berná-Serna JD, Guzmán-Aroca F, Berná-Mestre JD, et al. A new method for the prevention of skin laceration during vacuum-assisted breast biopsy. Br J Radiol. 2017. PMID: 28181826. doi:10.1259/bjr.20160866

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。