文献速递乳腺乳腺X线USMR

原发性乳腺肉瘤的影像学表现:首项多中心研究结果

Imaging findings of primary breast sarcoma: Results of a first multicenter study.
PubMed 文献 · Eur J Radiol · 2016-12-21

该研究回顾性检索德国10个放射科数据库2000至2011年组织学证实的原发性乳腺肉瘤病例,分析乳腺X线、超声和MRI表现并按BI-RADS第5版分类。结果显示原发性乳腺肉瘤无特征性影像表现,可模仿浸润性乳腺癌,应纳入上述影像表现的鉴别诊断。

要点

  • 乳腺X线常见不规则(53.3%[16/30])或卵形(30.0%[9/30])肿块,边缘多模糊(73.3%[22/30])。
  • 超声典型表现为不规则(79.2%[19/24])、低回声(62.5%[15/24])肿块,边缘模糊(79.2%[19/24])伴后方声影(79.2%[19/24])。
  • MRI多表现为不规则肿块(81.8%[9/11]),边缘不规则或毛刺状,动态增强呈快速初始信号增高伴延迟廓清。

核心结论

  • 原发性乳腺肉瘤无特征性影像表现,可模仿浸润性乳腺癌,应纳入上述影像表现的鉴别诊断。

研究设计与样本

  • 回顾性研究,检索德国10个放射科数据库2000至2011年组织学证实的原发性乳腺肉瘤病例,共42例女性患者(平均年龄62.0岁,范围30至86岁)。

关键影像表现/征象

  • 乳腺X线:不规则肿块53.3%[16/30],卵形肿块30.0%[9/30],边缘模糊73.3%[22/30],边缘微小分叶10%[3/30]。
  • 超声:不规则肿块79.2%[19/24],低回声62.5%[15/24],边缘模糊79.2%[19/24],后方声影79.2%[19/24]。
  • MRI:不规则肿块81.8%[9/11],边缘不规则或毛刺状,动态增强分析呈快速初始信号增高伴延迟廓清。

诊断标准与关键数值

  • 乳腺X线可用31例患者(33个病灶),超声图像可用24例患者(24个病灶),乳腺MRI可用10例患者(14个病灶)。
  • 乳腺表现按美国放射学会乳腺影像报告和数据系统(BI-RADS)第5版分类。

临床应用与阅片要点

  • 临床所有女性均表现为无痛性肿块。
  • 原发性乳腺肉瘤无特征性影像表现,可模仿浸润性乳腺癌,应纳入上述影像表现的鉴别诊断。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate imaging findings in patients with primary breast sarcoma (PBS).

MATERIALS AND METHODS: A retrospective search in the databases of 10 radiological departments in Germany from 2000 to 2011 was performed. Only histologically proven cases of PBS were included into the study. Mammography was available in 31 patients (33 lesions), ultrasound images in 24 patients (24 lesions), and for 10 patients (14 lesions) magnetic resonance imaging (MRI) of the breast was performed. The breast findings were classified according to the American College of Radiology Breast Imaging Reporting and Data Systems (BI-RADS) 5th edition categories. Collected data were evaluated by means of descriptive statistics.

RESULTS: Forty-two female patients (mean age 62.0 years, range, 30-86 years) were included in the study. Clinically, all women had painless lumps. Irregular (53.3% [16/30]) or oval (30.0% [9/30]) mass with indistinct (73.3% [22/30]) or microlobulated (10% [3/30]) margins were common findings on mammograms. Ultrasound revealed typically an irregular (79.2% [19/24]), hypoechoic (62.5% [15/24]) mass, with indistinct margins (79.2% [19/24]), and posterior acoustic shadowing (79.2% [19/24]). MRI showed irregular masses (81.8% [9/11]) with irregular or spiculated margins, and a rapid initial signal increase with a delayed washout in kinetic analysis.

CONCLUSION: Overall, PBS has no pathognomonic imaging features and can mimic those of invasive mammary carcinoma. Breast sarcoma should be taken into the differential diagnosis of breast findings described above.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Wienbeck S, Meyer HJ, Herzog A, et al. Imaging findings of primary breast sarcoma: Results of a first multicenter study. Eur J Radiol. 2016. PMID: 28189193. doi:10.1016/j.ejrad.2016.12.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。