文献速递泌尿生殖介入腹部CT

完全内生性小肾肿块的CT引导活检:标准剂量与降低剂量CT协议的诊断率与并发症比较

CT-Guided Biopsy of Entirely Endophytic Small Renal Masses: Diagnostic Rates and Complications Using Standard-Dose and Reduced-Dose CT Protocols.
PubMed 文献 · AJR Am J Roentgenol · 2017-02-08

回顾性比较标准剂量与降低剂量CT引导下完全内生性小肾肿块(≤4 cm)活检的诊断率和并发症。降低剂量组29/31个病灶(94%)获诊断结果,标准剂量组42/43个病灶(98%)获诊断结果;两组均无需干预或住院的并发症。降低剂量组剂量长度乘积显著低于标准剂量组(152 ± 63 vs 574 ± 232 mGy×cm,p < 0.05),平均操作时间无显著差异。

要点

  • 降低剂量CT协议(参考管电流-曝光时间42.0 ± 7.5 mAs)活检完全内生性小肾肿块,94%获诊断结果,与标准剂量组98%相似。
  • 两组均无需要干预或住院的并发症。
  • 降低剂量组剂量长度乘积显著低于标准剂量组(152 ± 63 vs 574 ± 232 mGy×cm,p < 0.05)。

核心结论

  • 使用降低剂量CT协议引导完全内生性小肾肿块活检,可获得与标准剂量CT协议相似的诊断结果,且不增加并发症率或操作时间。

研究设计与样本

  • 回顾性图表和影像review,共73例患者74个肿瘤(≤4 cm),标准剂量组43个病灶(平均参考管电流-曝光时间205.0 ± 19.0 mAs),降低剂量组31个病灶(参考管电流-曝光时间42.0 ± 7.5 mAs)。

诊断标准与关键数值

  • 降低剂量组31个病灶中29个(94%)获诊断结果,标准剂量组43个病灶中42个(98%)获诊断结果。
  • 两组均无需要干预或住院的并发症。
  • 剂量长度乘积标准剂量组574 ± 232 mGy×cm vs 降低剂量组152 ± 63 mGy×cm,标准剂量组显著更高(p < 0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The objective of this study was to compare diagnostic rates and complications using standard-dose and reduced-dose CT protocols for CT-guided biopsies of entirely endophytic small renal masses.

MATERIALS AND METHODS: A total of 73 patients with 74 tumors underwent CT-guided biopsy of entirely endophytic small renal masses (≤ 4 cm). Diagnostic rates, histologic findings, radiation doses, complication rates, and procedure duration were assessed by retrospective review of charts and images and were compared for the standard-dose and reduced-dose groups.

RESULTS: Biopsy was performed using the standard-dose CT protocol (mean reference tube current-exposure time setting, 205.0 ± 19.0 [SD] mAs) for 43 lesions, and the reduced-dose CT protocol (reference tube current-exposure time setting, 42.0 ± 7.5 mAs) for 31 lesions. In the reduced-dose group, there were 29 lesions (94%) with diagnostic results. In the standard-dose group, biopsies of 42 lesions (98%) yielded diagnostic results. No complications that needed intervention or hospitalization occurred in either group. The dose-length product (DLP) was significantly higher in the standard-dose group than the reduced-dose group (574 ± 232 vs 152 ± 63 mGy × cm, respectively; p < 0.05). The mean procedure duration did not differ significantly for the two groups.

CONCLUSION: Biopsy of entirely endophytic small renal masses that is performed with guidance using a reduced-dose CT protocol gives diagnostic results similar to a standard-dose CT protocol without any increase in complication rate or procedure duration.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Kim MH. CT-Guided Biopsy of Entirely Endophytic Small Renal Masses: Diagnostic Rates and Complications Using Standard-Dose and Reduced-Dose CT Protocols. AJR Am J Roentgenol. 2017. PMID: 28177700. doi:10.2214/AJR.16.16944

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。