文献速递骨肌USCT

联合高回声聚集与双轮廓征提高超声检测痛风单钠尿酸盐沉积的敏感性

Combining Hyperechoic Aggregates and the Double-Contour Sign Increases the Sensitivity of Sonography for Detection of Monosodium Urate Deposits in Gout.
PubMed 文献 · J Ultrasound Med · 2017-02-27

研究纳入70例急性痛风患者,对195个有症状关节及等量无症状关节分别单独及联合评估高回声聚集与双轮廓征,以双能CT确定的MSU沉积为参照。联合两种征象时患者阳性率97.14%,高于单独双轮廓征的74.29%与单独高回声聚集的63.89%。结论认为联合两种征象可提高超声检测痛风关节MSU结晶沉积的敏感性。

要点

  • 联合高回声聚集与双轮廓征可提高超声检出痛风MSU沉积的敏感性。
  • 有症状下肢关节联合征象阳性率98.06%,高于单独双轮廓征92.23%与单独高回声聚集41.75%。
  • 有症状上肢关节单独双轮廓征阳性率46.74%,低于单独高回声聚集70.65%。

核心结论

  • 高回声聚集与双轮廓征联合应用,较单独使用任一征象更能提高超声检测痛风关节MSU结晶沉积的敏感性。

研究设计与样本

  • 对70例急性痛风患者的有症状关节及对侧无症状关节行超声评估,所有患者至少1个有症状关节经双能CT确定存在MSU沉积。

关键影像表现/征象

  • 高回声聚集与双轮廓征为超声检测痛风MSU结晶沉积的两种征象。
  • 有症状上肢关节中双轮廓征阳性率46.74%(43/92),高回声聚集阳性率70.65%(65/92)。
  • 有症状下肢关节中双轮廓征阳性率92.23%(95/103),高回声聚集阳性率41.75%(43/103)。

诊断标准与关键数值

  • 患者水平联合征象阳性率97.14%(68/70),单独双轮廓征74.29%(52/70),单独高回声聚集63.89%(46/70)。
  • 有症状上肢关节联合征象阳性率86.96%(80/92)。
  • 有症状下肢关节联合征象阳性率98.06%(101/103)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the sensitivities of individual and combined sonography of hyperechoic aggregates and the double-contour sign in detecting monosodium urate (MSU) crystal deposits in gouty joints.

METHODS: Monosodium urate crystal deposits in symptomatic and contralateral asymptomatic joints of 70 patients with acute gout were evaluated by sonography of hyperechoic aggregates and the double-contour sign individually and in combination. All patients with acute gout in this study had at least 1 symptomatic joint with MSU deposits determined by dual-energy computed tomography.

RESULTS: Of 195 symptomatic joints (92 in the upper limbs and 103 in the lower limbs) and an equal number of asymptomatic joints: (1) 97.14% (68 of 70) of patients had hyperechoic aggregate/double-contour sign-positive joints versus 74.29% (52 of 70) with double-contour sign-positive and 63.89% (46 of 70) with hyperechoic aggregate-positive joints; (2) 86.96% (80 of 92) of the symptomatic upper limb joints were double-contour sign/hyperechoic aggregate positive versus 46.74% (43 of 92) that were double-contour sign positive and 70.65% (65 of 92) that were hyperechoic aggregate positive; and (3) 98.06% (101 of 103) of the symptomatic lower limb joints were double-contour sign/hyperechoic aggregate positive versus 92.23% (95 of 103) that were double-contour sign positive and 41.75% (43 of 103) that were hyperechoic aggregate positive.

CONCLUSIONS: Hyperechoic aggregates and the double-contour sign in combination improve the investigative sensitivity of sonography than either hyperechoic aggregates or the double-contour sign individually for detecting MSU crystal deposits in gouty joints.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Zhu L, Zheng S, Wang W, et al. Combining Hyperechoic Aggregates and the Double-Contour Sign Increases the Sensitivity of Sonography for Detection of Monosodium Urate Deposits in Gout. J Ultrasound Med. 2017. PMID: 28240795. doi:10.7863/ultra.16.03046

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。