本研究纳入28例疑似胆漏患者,回顾性分析动态T1加权钆塞酸二钠增强MR胆管造影检测活动性胆漏的诊断价值,其准确率、敏感度和特异度分别为92.9%、90.5%和100%(p < 0.001);19例患者发现胆漏征象,其中肝胆期组7例(36.8%)、延迟期组12例(63.2%),两组实验室检查结果及T2加权MR胆管造影胆管扩张表现差异均无统计学意义(p > 0.05)。

要点

  • 动态T1加权钆塞酸二钠增强MR胆管造影检测胆漏的准确率92.9%、敏感度90.5%、特异度100%(p < 0.001)。
  • 3例延迟期胆漏患者实验室检查结果及胆管直径均正常。

核心结论

  • 动态T1加权钆塞酸二钠增强MR胆管造影是检测胆漏的有用无创诊断工具;即使肝胆期胆道树显示充分且肝功能试验、总胆红素水平及胆管直径正常,仍可能需要延长延迟期成像以检测胆漏。

研究设计与样本

  • 回顾性研究,纳入2013年2月至2016年6月在本机构因疑似胆漏行常规T2加权MR胆管造影和T1加权钆塞酸二钠增强MR胆管造影的28例患者,由三名放射科医师共识回顾性分析图像,并与临床资料、随访检查及侵入性/手术操作结果对照。

诊断标准与关键数值

  • 动态钆塞酸二钠增强T1加权MR胆管造影检测胆漏的准确率为92.9%、敏感度为90.5%、特异度为100%(p < 0.001);按注射钆塞酸二钠至MR胆管造影首次显示胆漏征象的间隔时间分为肝胆期(20-30 min)组和延迟期(60-390 min)组。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the diagnostic value of dynamic T1 weighted (T1w) gadolinium ethoxybenzyl diethylenetriamine penta-acetic acid (Gd-EOB-DTPA)-enhanced MR cholangiography (MRC) for the detection of active bile leaks.

METHODS: A total of 28 patients with suspected biliary leakage who underwent routine T2 weighted (T2w) MRC and T1w GD-EOB-DTPA-enhanced MRC at our institution from February 2013 to June 2016 were included in this study. The image sets were retrospectively analyzed in consensus by three radiologists. T1w Gd-EOB-DTPA-enhanced MRC findings were correlated with clinical data, follow-up examinations and findings of invasive/surgical procedures. Patients with positive bile leak findings in Gd-EOB-DTPA-enhanced MRC were divided into hepatobiliary phase (HBP) (20-30 min) and delayed phase (DP) (60-390 min) group according to elapsed time between Gd-EOB-DTPA injection and initial bile leak findings in MRC images. These groups were compared in terms of laboratory test results (total bilirubin, liver enzymes) and the presence of bile duct dilatation in T2w MRC images.

RESULTS: In each patient, visualization of bile ducts was sufficient in the HBP. The accuracy, sensitivity and specificity of dynamic Gd-EOB-DTPA-enhanced T1w MRC in the detection of biliary leaks were 92.9%, 90.5% and 100%, respectively (p < 0.001). 19 of 28 patients had bile leak findings in T1w Gd-EOB-DTPA-enhanced MRC [HBP group: N = 7 (36.8%), DP group: N = 12 (63.2%)]. There was no statistically significant difference in terms of laboratory test results and the presence of bile duct dilatation between HBP and DP group (p > 0.05). Three patients, each of them in DP group, showed normal laboratory test results and bile duct diameters.

CONCLUSION: Dynamic T1w Gd-EOB-DTPA-enhanced MRC is a useful non-invasive diagnostic tool to detect bile leak. Advances in knowledge: Prolonged DP imaging may be required for bile leak detection even if visualization of biliary tree is sufficient in HBP and liver function tests, total bilirubin levels and bile duct diameters are normal.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Kul M, Erden A, Düşünceli Atman E, et al. Diagnostic value of Gd-EOB-DTPA-enhanced MR cholangiography in non-invasive detection of postoperative bile leakage. Br J Radiol. 2017. PMID: 28181823. doi:10.1259/bjr.20160847

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。