文献速递骨肌技术与安全US

动态活动中腰多裂肌与腹横肌超声测量的信度与精密度

Reliability and Precision of Sonography of the Lumbar Multifidus and Transversus Abdominis During Dynamic Activities.
PubMed 文献 · J Ultrasound Med · 2017-02-02

研究纳入15名无症状受试者,在腹部内收、直腿抬高、对侧臂抬举(负重与不负重)、跑步机步行及功能性再适应运动设备等多种静态与动态条件下,用徒手超声测量腰多裂肌与腹横肌的绝对厚度及相对厚度变化,评估组内信度与测量精密度。结果显示各条件下绝对与相对厚度的信度均为良好至优秀,腰多裂肌绝对厚度测量精密度≤3.8 mm、腹横肌≤0.7 mm,相对厚度精密度腰多裂肌≤7.6%、腹横肌≤13.6%。结论认为徒手超声在相对静态与动态运动中测量深层脊柱肌肉厚度可获得可接受的信度与精密度。

要点

  • 各运动条件下腰多裂肌与腹横肌绝对及相对厚度的组内信度均为良好至优秀。
  • 腹横肌绝对厚度测量精密度优于腰多裂肌,前者≤0.7 mm、后者≤3.8 mm。
  • 相对厚度测量中腹横肌精密度变异较大,腹部内收动作时≤13.6%。

核心结论

  • 徒手超声在相对静态与动态运动中测量深层脊柱肌肉绝对与相对厚度可获得可接受的信度与精密度。

研究设计与样本

  • 研究纳入15名无症状受试者,由同一评估者用徒手超声测量腰多裂肌与腹横肌厚度,以组内相关系数评估日内与日间信度、以测量标准误评估测量精密度。

诊断标准与关键数值

  • 腰多裂肌绝对厚度测量精密度:不负重对侧臂抬举≤2.8 mm,负重对侧臂抬举≤1.8 mm,跑步机步行≤3.1 mm,功能性再适应运动设备≤3.8 mm。
  • 腹横肌绝对厚度测量精密度:腹部内收动作≤0.6 mm,主动直腿抬高≤0.5 mm,跑步机步行≤0.7 mm,功能性再适应运动设备≤0.5 mm。
  • 腰多裂肌相对厚度测量精密度:不负重对侧臂抬举≤3.7%,负重对侧臂抬举≤3.8%,跑步机步行≤6.3%,功能性再适应运动设备≤7.6%。
  • 腹横肌相对厚度测量精密度:腹部内收动作≤13.6%,主动直腿抬高≤6.9%,跑步机步行≤11.1%,功能性再适应运动设备≤7.2%。

临床应用与阅片要点

  • 原文结论认为徒手超声可用于相对静态与动态运动中深层脊柱肌肉厚度的绝对与相对测量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine the intrarater reliability and precision of lumbar multifidus and transversus abdominis thickness measurements using freehand sonography in a range of static and dynamic conditions.

METHODS: Fifteen asymptomatic participants performed a range of exercises while sonography was used to measure absolute muscle thickness and changes in muscle thickness from rest. Exercise conditions included the abdominal drawing-in maneuver, active straight leg raise, contralateral arm lift, both unloaded and loaded, treadmill walking, and using the Functional Readaptive Exercise Device. Intraday and interday reliability was assessed by intraclass correlation coefficients, and the standard error of measurement was used to assess measurement precision.

RESULTS: Good to excellent reliability was achieved for absolute transversus abdominis and lumbar multifidus thickness in all conditions. Measurement precision for absolute lumbar multifidus thickness was ≤2.8 mm for the unloaded contralateral arm lift, ≤1.8 mm for the loaded contralateral arm lift, ≤3.1 mm for treadmill walking, and ≤3.8 mm for the Functional Readaptive Exercise Device; for absolute transversus abdominis thickness, precision was ≤0.6 mm for the abdominal drawing-in maneuver, ≤0.5 mm for the active straight leg raise, ≤0.7 mm for treadmill walking, and ≤0.5 mm for the Functional Readaptive Exercise Device. Good to excellent reliability was achieved for relative transversus abdominis and lumbar multifidus thickness in all conditions. Measurement precision for relative lumbar multifidus thickness was ≤3.7% for the unloaded contralateral arm lift, ≤3.8% for the loaded contralateral arm lift, ≤6.3% for treadmill walking, and ≤7.6% for the Functional Readaptive Exercise Device; for relative transversus abdominis thickness, precision was ≤13.6% for the abdominal drawing-in maneuver, ≤6.9% for the active straight leg raise, ≤11.1% for treadmill walking, and ≤7.2% for the Functional Readaptive Exercise Device.

CONCLUSIONS: Acceptable reliability and precision of measurement is achieved for absolute and relative measures of deep spinal muscle thickness using freehand sonography in relatively static and dynamic exercises.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Gibbon KC, Debuse D, Hibbs A, et al. Reliability and Precision of Sonography of the Lumbar Multifidus and Transversus Abdominis During Dynamic Activities. J Ultrasound Med. 2017. PMID: 28150321. doi:10.7863/ultra.16.03059

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。