文献速递外周血管腹部CT

联合管电压选择与体重方案在不影响图像质量的前提下降低腹主动脉CT血管成像碘对比剂用量

Reducing Iodine Contrast Volume in CT Angiography of the Abdominal Aorta Using Integrated Tube Potential Selection and Weight-Based Method Without Compromising Image Quality.
PubMed 文献 · AJR Am J Roentgenol · 2017-01-01

本研究探讨在腹主动脉CT血管成像(CTA)中,采用包含管电压选择和体重分层的方案能否在维持图像质量的同时降低碘对比剂用量。50例低碘CTA与36例自身对照及50例体型匹配对照相比,对比剂用量平均降低63%(49 mL vs 133 mL和138 mL),图像质量与诊断信心可接受率超过97%,主动脉强化程度组间相似。

要点

  • 基于管电压选择和体重的方案使腹主动脉CTA对比剂用量从133 mL降至49 mL,降幅63%。
  • 低碘CTA中超过97%的检查图像质量和诊断信心可接受(盲法50/50,非盲法35/36)。
  • 低碘CTA与对照组的主动脉强化程度相似,组间差异无统计学意义。

核心结论

  • 包含管电压选择的体重方案可在腹主动脉CTA中使用显著更低体积的碘对比剂,同时维持可接受的图像质量。

研究设计与样本

  • 研究纳入接受腹主动脉CTA的患者,低碘组使用根据管电压和体重制定的表格决定对比剂用量;比较低碘CTA、自身对照CTA(既往检查)和体型匹配对照CTA,由三名血管放射科医师在盲法下独立阅片,并进行非盲法侧对侧比较;采用Wilcoxon符号秩检验进行统计学比较。

关键影像表现/征象

  • 低碘CTA、自身对照CTA和体型匹配对照CTA的例数分别为50例、36例和50例。
  • 低碘CTA的平均对比剂用量为49 mL,自身对照CTA为133 mL,体型匹配对照CTA为138 mL,低碘方案对比剂用量降低63%。
  • 低碘CTA的平均容积CT剂量指数为15.1 mGy,自身对照CTA为18.8 mGy(p < 0.001),体型匹配对照CTA为17.1 mGy(p = 0.11)。
  • 低碘CTA在盲法阅片(50/50)和非盲法比较(35/36)中,超过97%的检查图像质量和诊断信心可接受。
  • 各组间主动脉强化程度相似(p = 0.13-0.71)。

临床应用与阅片要点

  • 采用包含管电压选择和体重分层的方案,可在腹主动脉CTA中显著降低碘对比剂用量而不影响图像质量可接受性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study is to determine whether image quality was maintained when a weight-based protocol incorporating tube potential selection was used to select lower iodine contrast volumes for aortic CT angiography (CTA).

MATERIALS AND METHODS: Patients with potentially decreased renal function underwent CTA performed with the iodinated contrast volume determined using a table incorporating different tube potentials and patient weights. The image quality of CTA examinations performed with a reduced iodine volume (hereafter known as "low-iodine CTA examinations"), internal control CTA examinations (i.e., prior examinations), and size-matched control CTA examinations was evaluated in separate reading sessions conducted by three vascular radiologists who were blinded as to the contrast volume and tube potential used. Side-by-side unblinded comparison of the examinations was also performed. Aortic attenuation and the contrast-to-noise ratio were measured. Comparisons were performed using the Wilcoxon signed rank test.

RESULTS: Fifty low-iodine CTA examinations, 36 internal control CTA examinations, and 50 size-matched control CTA examinations were performed. Contrast volumes were 63% lower when the protocol based on tube potential and patient weight was used (mean contrast volume, 49 mL for low-iodine CTA vs 133 mL for internal control CTA and 138 mL for size-matched control CTA). The mean volume CT dose index was 15.1 mGy for low-iodine CTA versus 18.8 mGy for internal control CTA (p < 0.001), and 15.3 mGy for low-iodine CTA versus 17.1 mGy for size-matched control CTA (p = 0.11). Of the image quality and diagnostic confidence evaluations for low-iodine CTA examinations, over 97% had acceptable image quality and diagnostic confidence for blinded (50/50) and unblinded (35/36) comparisons. Aortic attenuation was similar between groups (p = 0.13-0.71).

CONCLUSION: A weight-based protocol that incorporates tube potential selection allows the use of substantially lower volumes of iodinated contrast material in aortic CTA while maintaining acceptable image quality.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Vasconcelos R, Vrtiska TJ, Foley TA, et al. Reducing Iodine Contrast Volume in CT Angiography of the Abdominal Aorta Using Integrated Tube Potential Selection and Weight-Based Method Without Compromising Image Quality. AJR Am J Roentgenol. 2017. PMID: 28225687. doi:10.2214/AJR.16.16613

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。