文献速递心血管CT

迭代图像重建提高冠状动脉CT血管造影自动斑块负荷评估的准确性:与血管内超声的比较

Iterative Image Reconstruction Improves the Accuracy of Automated Plaque Burden Assessment in Coronary CT Angiography: A Comparison With Intravascular Ultrasound.
PubMed 文献 · AJR Am J Roentgenol · 2017-02-08

该离体研究以7条冠状动脉的CT血管造影(CCTA)与血管内超声(IVUS)图像为对象,比较滤波反投影(FBP)、自适应统计迭代重建(ASIR)和基于模型的迭代重建(MBIR)在自动及半自动斑块负荷评估中与IVUS的一致性。结果示MBIR与IVUS的相关性优于FBP和ASIR,且半自动评估结合MBIR准确性最高。

要点

  • MBIR与IVUS的斑块负荷相关性优于FBP和ASIR,全自动与半自动评估均如此。
  • 半自动评估中加入手动校正可改善与IVUS的相关性,且不依赖重建算法。
  • CCTA结合MBIR与半自动评估时斑块负荷定量准确性最高。

核心结论

  • 在CCTA斑块负荷定量中,MBIR与IVUS的相关性优于FBP和ASIR等传统重建算法,且不依赖全自动或半自动评估方法;采用MBIR数据结合半自动评估可获得最高的CCTA斑块负荷定量准确性。

研究设计与样本

  • 离体研究,获取7条冠状动脉的CCTA与IVUS图像;CT图像分别用FBP、ASIR和MBIR重建;以1 mm层间隔将CCTA与IVUS横断面图像配准;CCTA采用全自动(无手动校正)和半自动(允许手动校正血管壁边界)斑块负荷评估,IVUS手动测量斑块负荷;采用Pearson相关分析评估CCTA与IVUS的一致性。

诊断标准与关键数值

  • 共纳入173个对应横断面;IVUS测量的平均斑块负荷为63.39%±10.63%;CCTA全自动技术下平均斑块负荷:FBP为54.90%±11.70%,ASIR为53.34%±13.11%,MBIR为55.35%±12.22%;CCTA半自动技术下平均斑块负荷:FBP为54.90%±11.76%,ASIR为53.40%±12.85%,MBIR为57.09%±11.05%;半自动评估中39%的横断面进行了手动校正,手动校正独立于重建算法改善斑块负荷与IVUS的相关性(p<0.0001);MBIR优于FBP和ASIR且独立于评估方法:半自动评估中FBP r=0.59、ASIR r=0.52、MBIR r=0.78(均p<0.001),全自动评估中FBP r=0.40、ASIR r=0.37、MBIR r=0.53(均p<0.001)。

临床应用与阅片要点

  • 作者结论提示,CCTA斑块负荷定量采用MBIR数据结合半自动评估可获得最高准确性,手动校正可改善与IVUS的相关性且不依赖重建算法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study was to determine whether use of iterative image reconstruction algorithms improves the accuracy of coronary CT angiography (CCTA) compared with intravascular ultrasound (IVUS) in semiautomated plaque burden assessment.

MATERIALS AND METHODS: CCTA and IVUS images of seven coronary arteries were acquired ex vivo. CT images were reconstructed with filtered back projection (FBP) and adaptive statistical (ASIR) and model-based (MBIR) iterative reconstruction algorithms. Cross-sectional images of the arteries were coregistered between CCTA and IVUS in 1-mm increments. In CCTA, fully automated (without manual corrections) and semiautomated (allowing manual corrections of vessel wall boundaries) plaque burden assessments were performed for each of the reconstruction algorithms with commercially available software. In IVUS, plaque burden was measured manually. Agreement between CCTA and IVUS was determined with Pearson correlation.

RESULTS: A total of 173 corresponding cross sections were included. The mean plaque burden measured with IVUS was 63.39% ± 10.63%. With CCTA and the fully automated technique, it was 54.90% ± 11.70% with FBP, 53.34% ± 13.11% with ASIR, and 55.35% ± 12.22% with MBIR. With CCTA and the semiautomated technique mean plaque burden was 54.90% ± 11.76%, 53.40% ± 12.85%, 57.09% ± 11.05%. Manual correction of the semiautomated assessments was performed in 39% of all cross sections and improved plaque burden correlation with the IVUS assessment independently of reconstruction algorithm (p < 0.0001). Furthermore, MBIR was superior to FBP and ASIR independently of assessment method (semiautomated, r = 0.59 for FBP, r = 0.52 for ASIR, r = 0.78 for MBIR, all p < 0.001; fully automated, r = 0.40 for FBP, r = 0.37 for ASIR, r = 0.53 for MBIR, all p < 0.001).

CONCLUSION: For the quantification of plaque burden with CCTA, MBIR led to better correlation with IVUS than did traditional reconstruction algorithms such as FBP, independently of the use of a fully automated or semiautomated assessment approach. The highest accuracy for quantifying plaque burden with CCTA can be achieved by using MBIR data with semiautomated assessment.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Puchner SB, Ferencik M, Maehara A, et al. Iterative Image Reconstruction Improves the Accuracy of Automated Plaque Burden Assessment in Coronary CT Angiography: A Comparison With Intravascular Ultrasound. AJR Am J Roentgenol. 2017. PMID: 28177655. doi:10.2214/AJR.16.17187

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。