文献速递心血管CT

绝对延迟多期重建减少心脏CT中人工瓣膜相关及心房颤动相关伪影

Absolute-Delay Multiphase Reconstruction Reduces Prosthetic Valve-Related and Atrial Fibrillation-Related Artifacts at Cardiac CT.
PubMed 文献 · AJR Am J Roentgenol · 2017-02-22

纳入26例房颤患者共40枚机械瓣,比较绝对延迟与相对延迟多期重建的心脏CT图像质量。瓣膜区评分绝对延迟3.55±0.60高于相对延迟2.93±0.73,瓣下区3.35±0.66高于2.80±0.79(均p<0.0001);相对延迟重建中3枚瓣膜(7.5%)图像不可诊断,绝对延迟重建后均达诊断质量。

要点

  • 房颤患者机械瓣心脏CT中,绝对延迟多期重建的瓣膜区及瓣下区图像质量评分均高于相对延迟重建。
  • 相对延迟重建有3枚瓣膜(7.5%)图像不可诊断,改用绝对延迟重建后均达到诊断质量。
  • 对不规则心率患者的人工瓣膜评估,可优先采用绝对延迟多期重建以改善图像质量。

核心结论

  • 在心率不规则患者中,绝对延迟多期重建较相对延迟重建可改善机械瓣的CT图像质量。

研究设计与样本

  • 研究纳入26例房颤患者共40枚机械瓣,比较绝对延迟与相对延迟多期重建的心脏CT图像质量,采用4分制评估瓣膜区及瓣下区,使用配对t检验或Wilcoxon符号秩检验比较。

诊断标准与关键数值

  • 瓣膜区图像质量评分:相对延迟重建2.93±0.73 vs 绝对延迟重建3.55±0.60(p<0.0001)。
  • 瓣下区图像质量评分:相对延迟重建2.80±0.79 vs 绝对延迟重建3.35±0.66(p<0.0001)。
  • 总体图像质量评分为瓣膜区与瓣下区评分的均值。
  • 相对延迟重建中3枚瓣膜(7.5%)图像不可诊断,绝对延迟重建后3枚均达诊断质量(p<0.0001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The objective of our study was to compare the image quality of cardiac CT images of mechanical valves in patients with irregular heart rates (HRs) using absolute-delay multiphase reconstruction versus relative-delay multiphase reconstruction.

MATERIALS AND METHODS: A total of 26 patients with 40 mechanical valves who had atrial fibrillation during CT were included. The image quality of the CT scans was assessed for the subvalvular and valvular regions on a 4-point scale. The paired t test or Wilcoxon signed rank test was used to compare image quality scores between the relative-delay and absolute-delay reconstruction techniques. The overall image quality score was determined as the mean of the valvular and subvalvular region scores.

RESULTS: For valvular regions, the image quality scores were 2.93 ± 0.73 (mean ± SD) for the relative-delay reconstruction technique and 3.55 ± 0.60 for the absolute-delay reconstruction technique (p < 0.0001). For subvalvular regions, the image quality scores were 2.8 ± 2.80 ± 0.79 and 3.35 ± 0.66 for the relative- and absolute-delay reconstructions (p < 0.0001), respectively. The nondiagnostic image quality group consisted of relative-delay reconstruction images of three valves (7.5%); the image quality scores for the absolute-delay reconstruction images of all three valves were improved, and the absolute-delay reconstruction images of the three valves were of diagnostic quality (p < 0.0001).

CONCLUSION: Absolute-delay multiphase reconstruction can improve CT image quality of mechanical valves in patients with an irregular HR compared with relative-delay reconstruction.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Suh YJ, Im DJ, Hong YJ, et al. Absolute-Delay Multiphase Reconstruction Reduces Prosthetic Valve-Related and Atrial Fibrillation-Related Artifacts at Cardiac CT. AJR Am J Roentgenol. 2017. PMID: 28225640. doi:10.2214/AJR.16.16839

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。