冠状动脉CT血管成像中管腔衰减梯度及校正模型用于判定狭窄严重程度:基于双源CT的初步研究
回顾性纳入115例同时行CT冠状动脉成像(CTCA)和冠状动脉造影(CAG)的患者,在311支主要心外膜冠状动脉计算TAG、TAG-CCO和TAG-ExC;三种TAG均随狭窄程度加重而逐渐降低(P<0.001),TAG和TAG-ExC在全部血管中提高CTCA诊断效能(c统计量0.926 vs 0.907,P=0.018;0.922 vs 0.907,P=0.030),TAG-CCO未提高;在钙化血管(n=95)中加用TAG可显著重分类(净重分类改善0.143,P=0.038)。
要点
- TAG、TAG-CCO、TAG-ExC均随CAG狭窄严重程度增加而逐渐降低(P<0.001)。
- 全部血管中TAG和TAG-ExC较单用CTCA提高诊断效能,TAG-CCO未提高。
- 钙化血管(n=95)中CTCA加用TAG净重分类改善0.143(P=0.038)。
核心结论
- TAG和TAG-ExC提高了CTCA在全部血管中的诊断效能;CTCA加用TAG对钙化血管有显著重分类作用;TAG-CCO在判定狭窄严重程度上较单用CTCA的附加价值有限。
研究设计与样本
- 回顾性分析纳入115例同时行CTCA和CAG证实的患者,在311支主要心外膜冠状动脉计算TAG、TAG-CCO和TAG-ExC,以CAG为参考标准。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To compare the incremental value of transluminal attenuation gradient (TAG), TAG with corrected contrast opacification (TAG-CCO), and TAG with exclusion of calcified coronary segments (TAG-ExC) in determining the stenosis severity of coronary arteries using coronary angiography (CAG) as the reference standard.
MATERIALS AND METHODS: One hundred and fifteen patients who underwent computed tomography coronary angiography (CTCA) and confirmed by coronary angiography (CAG) were included in the retrospective analysis. TAG, TAG-CCO, and TAG-ExC were calculated in 311 major epicardial coronary arteries. Changes in different TAG models were compared with corresponding stenosis severities ascertained by CAG. The diagnostic performances of TAG, TAG-CCO, TAG-ExC, and the TAG/CTCA, TAG-CCO/CTCA, and TAG-ExC/CTCA combinations over CTCA alone in evaluating stenosis severity were then analysed and compared. Furthermore, the incremental value of the TAG and the corrected models in the reclassification of CTCA-evaluated stenosis severity were calculated.
RESULTS: TAG, TAG-CCO, and TAG-ExC decreased gradually with increased stenosis severity (p<0.001 for all TAG models). TAG and TAG-ExC improved the diagnostic performance over CTCA in total vessel evaluation (c statistic= 0.926 versus 0.907, p=0.018; c statistic= 0.922 versus 0.907, p=0.030, respectively), but TAG-CCO did not. Meanwhile, adding TAG to CTCA enabled a significant reclassification in calcified vessels (n=95; net reclassification improvement = 0.143, p=0.038).
CONCLUSIONS: TAG and TAG-ExC improved the diagnostic performance of CTCA in all vessels. Adding TAG to CTCA significantly reclassified the calcified vessels. The additional value of TAG-CCO over CTCA alone in determining the stenosis severity is limited.
引用
- Peng K, Xu N, Zhang L, et al. Transluminal attenuation gradient and corrected models in coronary CT angiography for determining stenosis severity: a primary study using dual-source CT. Clin Radiol. 2017. PMID: 28190514. doi:10.1016/j.crad.2017.01.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。