文献速递心血管儿科影像US

猪经食管超声心动图:基线的建立

Transesophageal Echocardiography in Swine: Establishment of a Baseline.
PubMed 文献 · Ultrasound Med Biol · 2017-02-16

本研究对45头德国长白猪或德国大白猪在非体外循环二尖瓣带瓣支架植入术前进行完整经食管超声心动图检查并测量血流动力学,提供标准超声心动图参数的基线值并与人类参考值比较,认为经食管超声心动图是合适的影像技术,所建立的基线参数可作为未来研究的参考。

要点

  • 猪经食管超声心动图检查可行,所测基线参数可作为未来猪模型研究的参考。
  • 研究提供了猪标准超声心动图参数的基线值,并在适当处与人类参考值比较。
  • 二尖瓣带瓣支架植入全程仅由实时三维经食管超声心动图引导。

核心结论

  • 经食管超声心动图在该实验猪模型中被证明是合适的影像技术。
  • 为广泛使用的猪模型建立的经食管超声心动图和血流动力学基线参数可作为未来研究的参考。

研究设计与样本

  • 研究纳入了45头德国长白猪或德国大白猪,平均体重49 ± 3 kg。
  • 在实验性非体外循环二尖瓣带瓣支架植入术前进行完整经食管超声心动图检查并评估血流动力学。
  • 瓣膜植入过程仅由实时三维经食管超声心动图引导。

诊断标准与关键数值

  • 提供标准超声心动图参数的基线值,并在适当处与人类参考值比较。

局限性

  • 原文指出迄今为止猪的经食管超声心动图数据有限,且已建立的猪模型标准值很少。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The porcine model is a commonly used animal model in cardiovascular research. Along with new innovative operative techniques, choice of the optimal imaging technique is crucial. Transesophageal echocardiography (TEE) is a reliable imaging tool is highly important in a large number of experimental evaluations. But so far, TEE data for swine are limited, and few standard values have been established for the porcine model. The experience and baseline results for TEE in 45 swine are presented in this study. A full TEE examination was conducted in 45 German landrace or German large white swine, with an average body weight of 49 ± 3 kg, before experimental off-pump mitral valved stent implantation. Additionally hemodynamic measurements were evaluated. The valve implantation procedure was guided solely by real-time 3-D TEE. Baseline values of standard echocardiographic parameters are provided and, where appropriate, compared with human reference values. TEE proved to be an adequate imaging technique in this experimental porcine animal model. The baseline TEE and hemodynamic parameters established for the widely used porcine model can serve as a reference in future studies.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Huenges K, Pokorny S, Berndt R, et al. Transesophageal Echocardiography in Swine: Establishment of a Baseline. Ultrasound Med Biol. 2017. PMID: 28214035. doi:10.1016/j.ultrasmedbio.2016.12.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。