新生儿及婴儿在80千伏峰值下使用低碘浓度对比剂行儿童CT心脏血管造影的主客观图像差异
本研究比较新生儿及婴儿在80 kVp下行CT心脏血管造影时使用碘克沙醇270(79例)与碘普罗胺370(62例)的主客观图像质量;两组对比增强的客观测量与主观图像质量评分均无统计学差异;阅片者仅凭视觉区分两种对比剂的敏感度42.8%、特异度59%、诊断准确率50%。
要点
- 两组对比增强与图像质量主客观评估均无统计学差异
- 阅片者仅凭视觉区分碘克沙醇270与碘普罗胺370的准确率为50%
- 作者认为碘克沙醇270在新生儿及婴儿80 kVp心脏CT血管造影中可获得最佳增强效果
核心结论
- 作者认为碘克沙醇270在新生儿及婴儿80 kVp儿童心脏CT血管造影中可获得最佳增强效果。
- 碘克沙醇270组与碘普罗胺370组的对比增强客观测量及主观图像质量评估均无统计学差异。
研究设计与样本
- 为比较碘克沙醇270组(79次CT扫描)与碘普罗胺370组(62次CT扫描)在≤1岁患者中的图像质量,于80 kVp下行CT心脏血管造影。
- 客观测量分析对比增强,并计算升主动脉与左心室的对比噪声比。
- 主观评估采用自行设计的四点量表,评价对比增强程度、图像噪声、运动伪影和整体图像质量,并评估阅片者仅凭视觉判断区分两种对比剂的阅片表现。
诊断标准与关键数值
- 阅片者仅凭视觉区分碘克沙醇270与碘普罗胺370的总体敏感度为42.8%、特异度为59%、诊断准确率为50%。
- 主观图像质量采用四点量表评价对比增强程度、图像噪声、运动伪影和整体图像质量。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Several recent studies showed the optimal contrast enhancement with a low-concentration and iso-osmolar contrast media in both adult and pediatric patients. However, low contrast media concentrations are not routinely used due to concerns of suboptimal enhancement of cardiac structures and small vessels.
OBJECTIVE: To evaluate the feasibility of using iso-osmolar contrast media containing a low iodine dose for CT cardiac angiography at 80 kilovolts (kVp) in neonates and infants.
MATERIALS AND METHODS: The iodixanol 270 group consisted of 79 CT scans and the iopromide 370 group of 62 CT scans in patients ≤1 year old. Objective measurement of the contrast enhancement was analyzed and contrast-to-noise ratios of the ascending aorta and left ventricle were calculated. Regarding subjective measurement, a four-point scale system was devised to evaluate degrees of contrast enhancement, image noise, motion artifact and overall image quality of each image set. Reader performance for correctly differentiating iodixanol 270 and iopromide 370 by visual assessment was evaluated.
RESULTS: Group objective and subjective measurements were nonsignificantly different. Overall sensitivity, specificity and diagnostic accuracy for correctly differentiating iodixanol 270 and iopromide 370 by visual assessment were 42.8%, 59%, and 50%, respectively.
CONCLUSION: The application of iodixanol 270 achieved optimal enhancement for performing pediatric cardiac CT angiography at 80 kVp in neonates and infants. Objective measurements of contrast enhancement and subjective image quality assessments were not statistically different in the iodixanol 270 and iopromide 370 groups.
引用
- Hwang JY, Choo KS, Choi YY, et al. Subjective and objective image differences in pediatric computed tomography cardiac angiography using lower iodine concentration. Pediatr Radiol. 2017. PMID: 28236133. doi:10.1007/s00247-017-3795-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。