文献速递胸部CT

单源双能CT:分析肺实质的最佳单能级是多少?

Single source dual energy CT: What is the optimal monochromatic energy level for the analysis of the lung parenchyma?
PubMed 文献 · Eur J Radiol · 2017-01-18

该研究回顾性纳入50例单源双能胸部CT检查,由两名胸部放射科医生独立评估40至140keV每5keV重建的单能图像,以确定肺实质分析的最佳单能级。72%的检查显示肺实质病变,两名读者选择最多的是50和55keV,合并50与55keV后,读者1在82%的患者中、读者2在92%的患者中认为该能级范围最佳,同时一致率为74%。结论认为50-55keV单能重建可获得最佳肺实质图像质量。

要点

  • 肺实质分析的最佳单能级为50-55keV,读者1在82%、读者2在92%的患者中选择该范围。
  • 两名读者选择50和55keV的合并一致率为74%。
  • 72%的检查存在肺实质病变,评估基于整体图像质量及病变显示清晰度。

核心结论

  • 光谱CT中肺实质的最佳图像质量在50-55keV单能重建下获得。

研究设计与样本

  • 回顾性分析一项经IRB批准的前瞻性单源双能胸部CT研究中的50例检查(男性58%,年龄64.8±16岁),由两名胸部放射科医生独立评估40至140keV每5keV重建的肺窗单能图像。

关键影像表现/征象

  • 72%的检查显示肺实质病变。
  • 读者1在52%的病例选择55keV、30%选择50keV、18%选择60keV。
  • 读者2在52%的病例选择50keV、40%选择55keV、6%选择60keV、2%选择40keV。

诊断标准与关键数值

  • 50和55keV能级分别被至少一名读者在64%和76%的患者中选择。
  • 合并50与55keV为一个类别后,读者1在82%的患者中、读者2在92%的患者中选择该范围为最佳,同时一致率为74%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine the optimal monochromatic energy level for lung parenchyma analysis in spectral CT.

METHODS: All 50 examinations (58% men, 64.8±16yo) from an IRB-approved prospective study on single-source dual energy chest CT were retrospectively included and analyzed. Monochromatic images in lung window reconstructed every 5keV from 40 to 140keV were independently assessed by two chest radiologists. Based on the overall image quality and the depiction/conspicuity of parenchymal lesions, each reader had to designate for every patient the keV level providing the best diagnostic and image quality.

RESULTS: 72% of the examinations exhibited parenchymal lesions. Reader 1 picked the 55keV monochromatic reconstruction in 52% of cases, 50 in 30% and 60 in 18%. Reader 2 chose 50keV in 52% cases, 55 in 40%, 60 in 6% and 40 in 2%. The 50 and 55keV levels were chosen by at least one reader in 64% and 76% of all patients, respectively. Merging 50 and 55keV into one category results in an optimal setting selected by reader 1 in 82% of patients and by reader 2 in 92%, with a 74% concomitant agreement.

CONCLUSION: The best image quality for lung parenchyma in spectral CT is obtained with the 50-55keV monochromatic reconstructions.

来源:Eur J Radiol,查看原文。版权归原作者所有。