文献速递心血管儿科影像MR

特纳综合征主动脉血流动力学的磁共振成像四维血流分析

Magnetic resonance imaging 4-D flow-based analysis of aortic hemodynamics in Turner syndrome.
PubMed 文献 · Pediatr Radiol · 2017-02-09

本研究用四维血流MRI比较25例特纳综合征患儿与16例年龄匹配健康女性对照的主动脉三维血流模式、管径和管壁参数,发现特纳综合征患者主动脉管径(经体表面积归一化)更大、升主动脉涡流增多、升主动脉和降主动脉螺旋流增高,且升主动脉异常螺旋或涡流者升主动脉管径更大,收缩期峰值管壁剪切应力、搏动指数和振荡剪切指数均显著降低。

要点

  • 特纳综合征患者升主动脉涡流增多、升主动脉和降主动脉螺旋流增高,与对照相比差异有统计学意义(均P<0.03)。
  • 升主动脉存在异常螺旋或涡流者,其升主动脉管径显著更大(P<0.03)。
  • 特纳综合征患者收缩期峰值管壁剪切应力、搏动指数和振荡剪切指数均显著低于对照。

核心结论

  • 四维血流MRI可揭示特纳综合征患者主动脉血流动力学和管壁剪切应力的改变,这些改变可能对主动脉夹层的发生有影响。

研究设计与样本

  • 研究论文,25例特纳综合征患者与16例女性健康对照(年龄均值±标准差分别为16±5岁和17±4岁),采用四维血流MRI测量覆盖胸主动脉的体内三维血流,以时间分辨三维路径线显示血流,由两名独立观察者对主动脉螺旋流和涡流进行视觉分级。

关键影像表现/征象

  • 特纳综合征患者升主动脉涡流较对照增多,升主动脉和降主动脉螺旋流较对照增高(均P<0.03)。
  • 升主动脉存在异常螺旋或涡流的患者,其升主动脉管径显著大于无此类异常者(P<0.03)。
  • 特纳综合征患者主动脉管径经体表面积归一化后显著大于对照。

诊断标准与关键数值

  • 在八个定义位点测量主动脉管径、收缩期峰值管壁剪切应力、搏动指数和振荡剪切指数。
  • 主动脉血流的螺旋流和涡流由两名独立观察者进行视觉分级。

临床应用与阅片要点

  • 四维血流MRI可显示主动脉三维血流模式,阅片时可关注升主动脉涡流及升主动脉、降主动脉螺旋流。
  • 升主动脉异常螺旋或涡流与升主动脉管径增大相关,报告中可结合管径与血流模式描述。
  • 特纳综合征患者收缩期峰值管壁剪切应力、搏动指数和振荡剪切指数低于对照,可作为管壁参数评估的参考。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Cardiovascular surveillance is important in Turner syndrome because of the increased risk of aortic dilation and dissection with consecutively increased mortality.

OBJECTIVE: To compare 4-D flow MRI for the characterization of aortic 3-D flow patterns, dimensions and vessel wall parameters in pediatric patients with Turner syndrome and age-matched controls.

MATERIALS AND METHODS: We performed 4-D flow MRI measuring in vivo 3-D blood flow with coverage of the thoracic aorta in 25 patients with Turner syndrome and in 16 female healthy controls (age mean ± standard deviation were 16 ± 5 years and 17 ± 4 years, respectively). Blood flow was visualized by time-resolved 3-D path lines. Visual grading of aortic flow in terms of helices and vortices was performed by two independent observers. Quantitative analysis included measurement of aortic diameters, quantification of peak systolic wall shear stress, pulsatility index and oscillatory shear index at eight defined sites.

RESULTS: Patients with Turner syndrome had significantly larger aortic diameters normalized to BSA, increased vortices in the ascending aorta and elevated helix flow in the ascending and descending aorta compared to controls (all P<0.03). Patients with abnormal helical or vortical flow in the ascending aorta had significantly larger diameters of the ascending aorta (P<0.03). Peak systolic wall shear stress, pulsatility index and oscillatory shear index were significantly lower in Turner patients compared to controls (p=0.02, p=0.002 and p=0.01 respectively).

CONCLUSION: Four-dimensional flow MRI provides new insights into the altered aortic hemodynamics and wall shear stress that could have an impact on the development of aortic dissections.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Arnold R, Neu M, Hirtler D, et al. Magnetic resonance imaging 4-D flow-based analysis of aortic hemodynamics in Turner syndrome. Pediatr Radiol. 2017. PMID: 28184962. doi:10.1007/s00247-016-3767-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。