文献速递胸部介入CT

经胸空心针活检非特异性良性病理结果:如何鉴别假阴性

Non-specific benign pathological results on transthoracic core-needle biopsy: how to differentiate false-negatives?
PubMed 文献 · Eur Radiol · 2017-02-10

研究纳入2009年1月至2011年12月接受锥形束CT引导经胸空心针活检的1108例患者共1116个肺部病灶,其中226个初始诊断为非特异性良性,最终24个(10.6%)证实为恶性,阴性预测值为89.4%(202/226);多因素分析显示部分实性结节(OR 3.95,P=0.022)与假阴性显著相关,而「肉芽肿性炎」病理结果(OR 0.04,P=0.022)和针尖精确位于目标内(OR 0.37,P=0.045)与假阴性显著负相关。

要点

  • 非特异性良性活检结果的阴性预测值为89.4%(202/226),即10.6%为假阴性。
  • 部分实性结节是假阴性的显著预测因素(OR 3.95,P=0.022)。
  • 病理报告「肉芽肿性炎」或针尖精确位于目标内提示真阴性可能大。

核心结论

  • 初始非特异性良性经胸空心针活检结果的阴性预测值为89.4%(202/226),部分实性结节是假阴性的显著正向预测因素,而病理结果为「肉芽肿性炎」及针尖精确位于目标内是假阴性的显著负向预测因素。

研究设计与样本

  • 研究类型为经胸空心针活检队列研究,2009年1月至2011年12月连续纳入1108例患者共1116个肺部病灶,均行锥形束CT引导下18G同轴切割针活检,其中226个初始诊断为非特异性良性的病灶纳入分析,通过查阅病历、影像或病理随访进行分类并分析假阴性相关变量。

诊断标准与关键数值

  • 非特异性良性活检结果的阴性预测值为89.4%(202/226);多因素分析显示部分实性结节与假阴性相关(OR 3.95,P=0.022),活检结果为「肉芽肿性炎」与假阴性相关(OR 0.04,P=0.022),针尖精确位于目标内与假阴性相关(OR 0.37,P=0.045)。

临床应用与阅片要点

  • 对于初始非特异性良性活检结果,若病灶为部分实性结节,需警惕假阴性可能;若病理报告「肉芽肿性炎」或影像确认针尖精确位于目标内,则假阴性风险较低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine the negative predictive value (NPV) of non-specific benign results from cone-beam CT (CBCT)-guided transthoracic core-needle biopsy (TTNB) and identify predicting factors for false-negative for malignancies.

METHODS: From January 2009-December 2011, 1,108 consecutive patients with 1,116 lung lesions underwent CBCT-guided TTNB using an 18-gauge coaxial cutting needle. Among them, 226 patients with 226 TTNBs, initially diagnosed as non-specific benign, were included in this study. The medical charts, radiological or pathological follow-ups were reviewed to classify false-negative and true-negative results and to identify which variables were associated with false-negatives.

RESULTS: Of 226 lesions, 24 (10.6%) were finally confirmed as malignancies and 202 (89.4%) as benign, of which the NPV was 89.4% (202/226). Multivariate analysis revealed that part-solid nodule (PSN) (odds ratio (OR), 3.95; P = 0.022), a biopsy result of 'granulomatous inflammation' (OR, 0.04; P = 0.022), and exact location of needle tip within targets (OR, 0.37; P = 0.045) were significantly associated with false-negatives among initial non-specific benign biopsy results.

CONCLUSION: The NPV of the non-specific benign biopsy was 89.4%. PSN was a significant positive indicator, but a biopsy result of 'granulomatous inflammation' and exact location of needle tip within targets were significant negative indicators for false-negatives.

KEY POINTS: • The negative predictive value of the non-specific benign biopsy was 89.4%. • A part-solid nodule is a significant predictor for false-negative biopsy (OR = 3.95). • Pathological diagnosis of granulomatous inflammation is a robust indicator for 'true-negatives'. • Identifying needle tip within target lesions is a significant predictor for 'true-negatives'.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Kim JI, Park CM, Kim H, et al. Non-specific benign pathological results on transthoracic core-needle biopsy: how to differentiate false-negatives? Eur Radiol. 2017. PMID: 28188426. doi:10.1007/s00330-017-4766-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。