文献速递神经技术与安全MR

无磁敏感伪影的快速全脑扩散加权磁共振成像:径向欠采样与迭代重建的单次激发STEAM序列

Rapid Diffusion-Weighted Magnetic Resonance Imaging of the Brain Without Susceptibility Artifacts: Single-Shot STEAM With Radial Undersampling and Iterative Reconstruction.
PubMed 文献 · Invest Radiol · 2017-01-01

本研究开发了一种结合单次激发刺激回波采集模式与径向欠采样及迭代正则化高斯-牛顿非线性反演的快速扩散加权MRI技术,在3T设备上对10名健康受试者和2例患者(缺血性病灶及表皮样囊肿)进行全脑成像,84秒和168秒采集分别获得1.5 mm和1.25 mm平面分辨率,表观扩散系数值与文献数据一致,结论认为该方法无磁敏感伪影、信噪比足够且扫描时间低于3分钟。

要点

  • 单次激发STEAM结合径向欠采样可减轻磁敏感伪影,全脑扩散加权成像84秒完成。
  • 84秒采集平面分辨率1.5 mm、层厚4 mm(55层);168秒采集平面分辨率1.25 mm、层厚3 mm(54层)。
  • 表观扩散系数值与文献数据一致,但更广泛的临床试验需要加速计算和在线重建。

核心结论

  • 所提出的扩散加权MRI方法无磁敏感问题、空间分辨率高、信噪比足够,全脑扫描时间临床可行且低于3分钟;更广泛的临床试验需要加速计算和在线重建。

研究设计与样本

  • 方法学研究,在3T MRI系统(64通道头线圈,80 mT·m梯度)上实施,纳入10名健康受试者和2例患者(分别为缺血性病灶和表皮样囊肿)进行评价。

关键影像表现/征象

  • 采集1幅非扩散加权图像和6幅不同扩散方向、b=1000 s·mm的扩散加权图像,获得高质量全脑平均扩散加权图像。
  • 总测量时间84秒时,平面内分辨率1.5 mm、层厚4 mm,共55层。
  • 总测量时间168秒时,平面内分辨率1.25 mm、层厚3 mm,共54层。
  • 表观扩散系数值与文献数据一致。

局限性

  • 更广泛的临床试验需要加速计算和在线重建。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The aim of this study was to develop a rapid diffusion-weighted (DW) magnetic resonance imaging (MRI) technique for whole-brain studies without susceptibility artifacts and measuring times below 3 minutes.

MATERIALS AND METHODS: The proposed method combines a DW spin-echo module with a single-shot stimulated echo acquisition mode MRI sequence. Previous deficiencies in image quality due to limited signal-to-noise ratio are compensated for (1) by radial undersampling to enhance the flip angle and thus the signal strength of stimulated echoes; (2) by defining the image reconstruction as a nonlinear inverse problem, which is solved by the iteratively regularized Gauss-Newton method; and (3) by denoising with use of a modified nonlocal means filter. The method was implemented on a 3 T MRI system (64-channel head coil, 80 mT · m gradients) and evaluated for 10 healthy subjects and 2 patients with an ischemic lesion and epidermoid cyst, respectively.

RESULTS: High-quality mean DW images of the entire brain were obtained by acquiring 1 non-DW image and 6 DW images with different diffusion directions at b = 1000 s · mm. The achievable resolution for a total measuring time of 84 seconds was 1.5 mm in plane with a section thickness of 4 mm (55 sections). A measuring time of 168 seconds allowed for an in-plane resolution of 1.25 mm and a section thickness of 3 mm (54 sections). Apparent diffusion coefficient values were in agreement with literature data.

CONCLUSIONS: The proposed method for DW MRI offers immunity against susceptibility problems, high spatial resolution, adequate signal-to-noise ratio and clinically feasible scan times of less than 3 minutes for whole-brain studies. More extended clinical trials require accelerated computation and online reconstruction.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Merrem A, Hofer S, Voit D, et al. Rapid Diffusion-Weighted Magnetic Resonance Imaging of the Brain Without Susceptibility Artifacts: Single-Shot STEAM With Radial Undersampling and Iterative Reconstruction. Invest Radiol. 2017. PMID: 28151734. doi:10.1097/RLI.0000000000000357

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。