文献速递神经MR

相位对比MRI脑脊液流动测量诊断正常压力脑积水:速度与容积参数的观察者一致性

Phase-Contrast MRI CSF Flow Measurements for the Diagnosis of Normal-Pressure Hydrocephalus: Observer Agreement of Velocity Versus Volume Parameters.
PubMed 文献 · AJR Am J Roentgenol · 2017-01-31

研究纳入32例受试者(对照组、正常压力脑积水(NPH)组、脑萎缩组),采用相位对比MRI手动勾画中脑导水管ROI分析脑脊液流动,比较不同流动参数的观察者一致性与诊断准确性。结果显示NPH组峰值收缩速度、峰值平均速度和每搏量均高于对照组和脑萎缩组,每搏量诊断准确性达100%,一致性优于峰值平均速度。

要点

  • 每搏量(stroke volume)诊断NPH的准确性为100%,观察者间和观察者内ICC分别为0.98和0.97。
  • 峰值平均速度诊断NPH的准确性为92.5-93.3%,ICC为0.88,重复性低于每搏量。
  • 峰值收缩速度不依赖ROI勾画,但诊断准确性最低,为82.7%。

核心结论

  • 每搏量较峰值平均速度具有更好的一致性和重复性,且诊断NPH更准确;峰值收缩速度缺乏变异性但准确性最低。

研究设计与样本

  • 研究纳入32例受试者,分为对照组、NPH组和脑萎缩组,均行相位对比MRI检查;由两名独立读者手动放置ROI进行脑脊液流动定量分析,读者1在首次测量3个月后重复测量以评估观察者间和观察者内一致性。

诊断标准与关键数值

  • NPH组峰值收缩速度、峰值平均速度和每搏量在所有读数中均显著高于对照组和脑萎缩组。
  • 峰值收缩速度诊断NPH的准确性为82.7%。
  • 峰值平均速度诊断NPH的准确性为92.5-93.3%(三次读数)。
  • 每搏量诊断NPH的准确性为100%(三次读数)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Manual segmentation of the aqueduct for CSF flow analysis may induce measurement variability. The aim of our study was to assess observer agreement of manual segmentation and to compare the repeatability and accuracy of different flow parameters in differentiating normal-pressure hydrocephalus (NPH) from brain atrophy.

SUBJECTS AND METHODS: Thirty-two subjects were included and were divided into three groups: control, NPH, and brain atrophy. Subjects underwent phase-contrast MRI. Quantitative analysis of aqueductal CSF flow using manual ROI placement was performed by two independent readers. Reader 1 repeated measurements 3 months after the first session to assess interobserver and intraobserver agreement. Intraclass correlation coefficients (ICCs), within-subject SD, and repeatability were calculated. Peak systolic velocity (PSV), peak mean velocity, and aqueductal CSF stroke volume, which we refer to as "stroke volume," were recorded and compared between the three patient groups. The ROC curves of diagnostic accuracy for NPH were compared.

RESULTS: PSV was ROI-independent, so only one measurement was obtained. The NPH group had significantly higher PSV, peak mean velocity, and stroke volume values in all readings than both the control and brain atrophy groups. The accuracy of PSV for the diagnosis of NPH was 82.7%, and the accuracy of peak mean velocity was 92.5-93.3% for the three readings. Stroke volume had perfect accuracy of 100% for the three readings. The stroke volume had higher ICCs (0.97 and 0.98) than the peak mean velocity (0.88). The intraobserver repeatability and interobserver repeatability of peak mean velocity were 1.9 cm/s, and the intraobserver repeatability and interobserver repeatability of stroke volume were 27.4 and 19.6 µL/cycle, respectively.

CONCLUSION: Stroke volume had better agreement and repeatability and was more accurate than peak mean velocity for the diagnosis of NPH. PSV lacks variability but was the least accurate.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Tawfik AM, Elsorogy L, Abdelghaffar R, et al. Phase-Contrast MRI CSF Flow Measurements for the Diagnosis of Normal-Pressure Hydrocephalus: Observer Agreement of Velocity Versus Volume Parameters. AJR Am J Roentgenol. 2017. PMID: 28140607. doi:10.2214/AJR.16.16995

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。