文献速递介入神经CTDSA

平板探测器CT及其在宽颈颅内动脉瘤血管内治疗中的应用——文献综述

Flat detector CT and its applications in the endovascular treatment of wide-necked intracranial aneurysms-A literature review.
PubMed 文献 · Eur J Radiol · 2016-12-26

本文综述了平板探测器CT(FDCT)在血管内神经外科中的应用经验,重点介绍其在宽颈颅内动脉瘤支架辅助弹簧圈栓塞和血流导向装置植入中的贡献。FDCT可在血管造影室内提供横断面成像,空间分辨率较高,有助于评估装置释放、定位及与载瘤血管和周围结构的关系。对比剂增强可扩展其诊断能力,但线束硬化伪影是部分病例的主要局限。

要点

  • FDCT在血管造影室内提供横断面成像,可清晰显示颅内支架或血流导向装置。
  • FDCT有助于评估装置释放、定位及其与载瘤血管和周围结构的关系。
  • 线束硬化伪影是部分病例的主要局限;静脉注射对比剂可降低并发症风险,使门诊检查成为可能。

核心结论

  • FDCT是一种在血管造影室内提供横断面成像的替代影像方法,在介入放射学各领域日益普及。

研究设计与样本

  • 文献综述,旨在概述已发表的关于FDCT在血管内神经外科中应用经验的研究,重点关注支架辅助弹簧圈栓塞和血流导向装置植入。

关键影像表现/征象

  • FDCT空间分辨率相对较高,可改善颅内支架或血流导向装置等腔内装置的显示。

诊断标准与关键数值

  • FDCT可评估装置释放和定位及其与载瘤血管和周围结构的关系。

临床应用与阅片要点

  • FDCT检查可在血管内操作过程中以及治疗前和治疗后成像时进行。

局限性

  • 线束硬化伪影是部分病例的主要限制。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Flat detector CT (FDCT) provides cross sectional imaging within an angiographic suite and is increasingly gaining popularity in various areas of interventional radiology, as an alternative imaging modality. Its relatively high spatial resolution improves visualization of intraluminal devices such as intracranial stents or flow-diverters. Device deployment and positioning, in relation to the parent vessel and surrounding structures, are easily assessible with FDCT. Furthermore, with contrast agent administration, it expands the diagnostic capabilities of this new imaging tool. However, beam-hardening artifacts is a major limitation in some cases. The examination can be performed both during the endovascular procedure and for pre- and post-treatment imaging. Intravenous contrast agent injection reduces the risk of complications, making it possible to perform this examination in the outpatient settings. The aim of this paper is to present an overview of published studies reporting experience with FDCT in the field of endovascular neurosurgery and in particular, FDCT's contribution in treatment of wide-necked intracranial aneurysms. The authors have focused specifically on stent-assisted coiling and flow-diverter implantation, since obtaining proper parent vessel wall apposition of these devices is essential for short- and long-term procedural outcomes.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Zwarzany Ł, Poncyljusz W, Burke TH, et al. Flat detector CT and its applications in the endovascular treatment of wide-necked intracranial aneurysms-A literature review. Eur J Radiol. 2016. PMID: 28189205. doi:10.1016/j.ejrad.2016.12.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。