基于分光光度法测量血栓厚度的体外声学溶栓检测方法

An In Vitro Assay for Sonothrombolysis Based on the Spectrophotometric Measurement of Clot Thickness.
PubMed 文献 · J Ultrasound Med · 2017-02-02

研究设计了一种使用片状血栓的体外声学溶栓检测系统,该检测池不显著干扰声场。用分光光度法沿4个方向测量100个点的血栓厚度,速率约4点/秒。仅用一片片状血栓即获得13个超声强度水平的声学溶栓效果,并用临床导向探头在0.7和0.3 W/cm²下确认了声学溶栓发生。

要点

  • 新型体外声学溶栓检测法用片状血栓和分光光度法测厚度,检测池不显著干扰声场。
  • 一片片状血栓可同时评估13个超声强度水平的溶栓效果,测量速率约4点/秒。
  • 临床导向探头在0.7和0.3 W/cm²强度下均确认了声学溶栓发生。

核心结论

  • 成功建立了一种简便高效的体外声学溶栓检测新方法,检测池对超声反射或驻波干预小,作者认为该方法对超声溶栓效果的基础分析非常有用。

研究设计与样本

  • 体外实验研究,设计血栓检测池并用片状血栓进行声学溶栓检测,使用人血浆制备片状血栓,以分光光度法测量血栓厚度。

关键影像表现/征象

  • 检测池不显著干预声场。
  • 沿4个方向100个点以约4点/秒速率分光光度法测量血栓厚度。
  • 仅用一片片状血栓获得13个超声强度水平的声学溶栓效果。
  • 临床导向探头在0.7和0.3 W/cm²下确认声学溶栓发生。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: For improved thrombolysis therapy based on ultrasound irradiation, researchers and practitioners would strongly benefit from an easy and efficient in vitro assay system of thrombolysis activity involving irradiated ultrasound. For the present study, we designed a new in vitro sonothrombolysis assay system using a sheet-type clot.

METHODS: We designed a cell for clot assay, and we confirmed that this clot cell did not significantly intervene in the acoustic field. Using human plasma, we made a sheet-type clot in the cell. Clot thicknesses at 100 points along 4 directions were measured photometrically at a rate of approximately 4 points/s.

RESULTS: The sonothrombolysis effects at 13 levels of ultrasonic intensity were obtained with only one sheet-type clot. With this method, we used a clinically oriented probe at 0.7 and 0.3 W/cm2 to confirm that sonothrombolysis took place.

CONCLUSIONS: We successfully established a new, easy, and efficient method for conducting in vitro sonothrombolysis assays. This method involves little intervention of either ultrasound reflection or standing waves in the clot cell. We believe that this new assay method is very useful for fundamental analyses of ultrasound's thrombolysis effects.