胸部双源双能量CT血管造影中基于衰减的kV对选择:对辐射剂量和图像质量的影响
前瞻性研究纳入118例疑似肺栓塞患者,在双源双能量肺栓塞方案中采用基于衰减的kV对选择,63例(53%)切换至80/140Sn kV对,平均扫描前CTDIvol从8.8 mGy降至7.5 mGy,平均剂量降低1.3 mGy(95% CI 1.2, 1.4; p < 0.001),相当于降低15%,且图像质量未受影响。
要点
- 基于衰减的kV对选择使53%的患者切换至80/140Sn kV对。
- 切换组平均剂量降低1.3 mGy(95% CI 1.2, 1.4; p < 0.001),相当于降低15%。
- 切换组与未切换组相比,调整体重后各肺动脉及肺叶碘图平均衰减显著更高,图像质量未受影响。
核心结论
- 在双源双能量检查中,基于衰减的kV对选择可行,可在不损害图像质量的前提下降低辐射剂量。
研究设计与样本
- 前瞻性研究,纳入118例疑似肺栓塞患者,采用双源双能量肺栓塞协议,评估基于衰减的kV对选择对辐射剂量和图像质量的影响。
关键影像表现/征象
- 切换组与未切换组相比,调整体重后,在全部5支肺动脉及所有肺叶的碘图上平均衰减显著更高。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The purpose of this study was to evaluate the impact of attenuation-based kilovoltage (kV) pair selection in dual source dual energy (DSDE)-pulmonary embolism (PE) protocol examinations on radiation dose savings and image quality.
METHODS: A prospective study was carried out on 118 patients with suspected PE. In patients in whom attenuation-based kV pair selection selected the 80/140Sn kV pair, the pre-scan 100/140Sn CTDIvol (computed tomography dose index volume) values were compared with the pre-scan 80/140Sn CTDIvol values. Subjective and objective image quality parameters were assessed.
RESULTS: Attenuation-based kV pair selection switched to the 80/140Sn kV pair ("switched" cohort) in 63 out of 118 patients (53%). The mean 100/140Sn pre-scan CTDIvol was 8.8 mGy, while the mean 80/140Sn pre-scan CTDIvol was 7.5 mGy. The average estimated dose reduction for the "switched" cohort was 1.3 mGy (95% CI 1.2, 1.4; p < 0.001), representing a 15% reduction in dose. After adjusting for patient weight, mean attenuation was significantly higher in the "switched" vs. "non-switched" cohorts in all five pulmonary arteries and in all lobes on iodine maps.
CONCLUSIONS: This study demonstrates that attenuation-based kV pair selection in DSDE examination is feasible and can offer radiation dose reduction without compromising image quality.
KEY POINTS: • Attenuation-based kV pair selection in dual energy examination is feasible. • It can offer radiation dose reduction to approximately 50% of patients. • Approximate 15% reduction in radiation dose was achieved using this technique. • The image quality is not compromised by use of attenuation-based kV pair selection.
引用
- Renapurkar RD, Primak A, Azok J, et al. Attenuation-based kV pair selection in dual source dual energy computed tomography angiography of the chest: impact on radiation dose and image quality. Eur Radiol. 2017. PMID: 28091793. doi:10.1007/s00330-016-4714-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。