采用身高校正指标并以脐为标志的聚焦CT用于儿童阑尾炎评估
该回顾性研究纳入270例疑似阑尾炎患儿,测量阑尾最头端至脐中心的距离并除以身高得到比值,取最大比值作为身高常数阈值。身高常数0.07可识别全部阑尾,估计平均辐射减少27%;0.03可识别97%阑尾,辐射减少43%。
要点
- 阑尾最头端均位于脐上10.5 cm以内。
- 身高常数0.07识别100%阑尾,估计辐射减少27%。
- 身高常数0.03识别97%阑尾,估计辐射减少43%。
核心结论
- 身高校正的聚焦腹部盆腔CT可能减少辐射暴露而不牺牲完整CT的诊断准确性。
研究设计与样本
- 回顾性研究,纳入270例18岁以下因疑似阑尾炎行CT检查的儿童;由一名儿科放射科医生测量阑尾最头端至脐中心的距离并除以身高得到比值;以最大距离/身高比值作为身高常数阈值。
关键影像表现/征象
- 在270例完整识别阑尾的患儿中,所有阑尾均位于脐上10.5 cm以内。
诊断标准与关键数值
- 身高常数0.07识别100%的阑尾,估计平均辐射减少27%(标准差±4.7)。
- 身高常数0.03识别97%的阑尾,估计辐射减少43%(标准差±4.3)。
临床应用与阅片要点
- 以身高常数乘以患儿身高可得出聚焦CT扫描的上界阈值。
- 身高常数0.07可覆盖全部阑尾,身高常数0.03覆盖97%阑尾。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Confirmation of appendicitis in children often requires CT. A focused CT scan that is limited to the lower abdomen/pelvis might help to reduce radiation exposure.
OBJECTIVE: To determine the position of the appendix relative to the umbilicus and derive a height-adjusted threshold for a focused CT that would identify most appendices.
MATERIALS AND METHODS: We conducted a retrospective study of children younger than 18 years who underwent a CT scan for suspected appendicitis. A pediatric radiologist determined the distance from the most cephalad portion of the appendix to the center of the umbilicus. This distance was divided by the child's height to create a ratio for each child. We then assessed the largest of these distance/height ratios ("height constants") as potential height-adjusted thresholds that, when multiplied by any patient's height, would yield the superior threshold for the focused CT scan. Radiation reduction was calculated as percentage decrease in scan length compared to a complete abdominopelvic CT.
RESULTS: Of 270 patients whose entire appendix was identified on CT, all were identified within 10.5 cm above the umbilicus. A focused CT using a height constant of 0.07 identified 100% of the appendices visualized on the complete CT scan and resulted in an estimated mean percentage radiation reduction of 27% (standard deviation [SD] +/-4.7). If a height constant of 0.03 was used, 97% of appendices were identified and the estimated radiation reduction was 43% (SD +/-4.3).
CONCLUSION: A height-adjusted focused abdominopelvic CT scan might reduce radiation exposure without sacrificing the diagnostic accuracy of the complete CT scan.
引用
- Roberts S, Nixon AF, Meltzer JA, et al. Focused CT using a height-adjusted metric and the umbilicus as a landmark for children undergoing evaluation for appendicitis. Pediatr Radiol. 2017. PMID: 28062934. doi:10.1007/s00247-016-3756-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。