差分强度投影用于颈动脉超声造影图像中斑块新生血管的可视化与定量
研究开发差分强度投影(DIP)新图像处理方法,用于颈动脉超声造影非线性图像序列中斑块内新生血管(IPN)的可视化与定量。DIP利用局部时间最大值与局部时间平均值的差异识别气泡信号,在体外模体测量后对48例患者的24个图像序列进行运动校正分析。DIP的微血管面积(r=0.83,p<0.001)和微血管密度(r=0.77,p<0.001)与专家视觉分级良好相关,优于最大强度投影(MIP)的r=0.26和0.23。
要点
- DIP利用局部时间最大值与平均值的差异识别气泡,较MIP更特异检测气泡信号。
- DIP的微血管面积与专家视觉分级相关r=0.83(p<0.001),微血管密度r=0.77(p<0.001)。
- MIP在同一数据上微血管面积和密度的相关系数分别为r=0.26和r=0.23。
核心结论
- DIP方法在颈动脉超声造影图像中对IPN的定量方面展现出很大潜力。
研究设计与样本
- 研究开发了差分强度投影(DIP)图像处理方法,先进行实验室模体的体外测量,再选取48例患者的24个颈动脉超声造影非线性图像序列进行运动校正后分析,并与最大强度投影(MIP)和视觉评估比较。
关键影像表现/征象
- DIP能显著减少非线性传播组织伪影,在检测气泡信号方面比MIP更具特异性。
- DIP能揭示对应MIP图像中埋藏于组织伪影内的微气泡信号。
诊断标准与关键数值
- DIP微血管面积与专家视觉分级相关系数r=0.83(p<0.001)。
- DIP微血管密度与专家视觉分级相关系数r=0.77(p<0.001)。
- MIP在同一数据上微血管面积相关系数r=0.26、微血管密度相关系数r=0.23。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Studies have reported that intraplaque neovascularisation (IPN) is closely correlated with plaque vulnerability. In this study, a new image processing approach, differential intensity projection (DIP), was developed to visualise and quantify IPN in contrast-enhanced non-linear ultrasound image sequences of carotid arteries. DIP used the difference between the local temporal maximum and the local temporal average signals to identify bubbles against tissue non-linear artefact and noise. The total absolute and relative areas occupied by bubbles within each plaque were calculated to quantify IPN. In vitro measurements on a laboratory phantom were made, followed by in vivo measurements in which 24 contrast-enhanced non-linear ultrasound image sequences of carotid arteries from 48 patients were selected and motion corrected. The results using DIP were compared with those obtained by maximum intensity projection (MIP) and visual assessment. The results indicated that DIP can significantly reduce non-linear propagation tissue artefacts and is much more specific in detecting bubble signals than MIP, being able to reveal microbubble signals that are buried in tissue artefacts in the corresponding MIP image. A good correlation was found between microvascular area (MVA) (r = 0.83, p < 0.001)/microvascular density (r = 0.77, p < 0.001) obtained using DIP and the corresponding expert visual grades, comparing favourably to r = 0.26 and 0.23 obtained using MIP on the same data. In conclusion, the proposed method exhibits great potential in quantification of IPN in contrast-enhanced ultrasound images of carotid arteries.
引用
- Cheung WK, Shah BN, Stanziola A, et al. Differential Intensity Projection for Visualisation and Quantification of Plaque Neovascularisation in Contrast-Enhanced Ultrasound Images of Carotid Arteries. Ultrasound Med Biol. 2017. PMID: 28094067. doi:10.1016/j.ultrasmedbio.2016.11.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。