腰椎神经根受压的诊断:3T三维各向同性T2加权Turbo Spin-Echo SPACE序列性能评估
研究纳入37例患者共39个神经根受压节段、78个神经根,比较2D TSE、3D SPACE(轴位+矢状位或全部平面)及2D+3D联合对神经根受压的分级诊断性能。结果显示各影像组ROC曲线面积无显著差异,仅读者1的2D+3D联合(0.843)优于2D(0.802)、读者2的2D+3D联合(0.820)优于3D全部平面(0.765)。结论认为3D各向同性T2加权TSE序列与2D TSE序列诊断性能无显著差异,联合2D与3D可能提高诊断准确率。
要点
- 3D各向同性T2加权TSE SPACE序列对腰椎神经根受压的诊断性能与2D TSE序列无显著差异。
- 2D与3D联合在部分读者中ROC曲线面积优于单独2D或单独3D全部平面。
- 神经根受压分级采用0至3级,由两名读者独立评估。
核心结论
- 3D各向同性T2加权TSE序列(轴位+矢状位或全部平面)对腰椎神经根受压的评估性能与2D TSE序列无显著差异,联合2D与3D可能提高诊断准确率。
研究设计与样本
- 回顾性分析37例在3T行脊柱MRI(含2D与3D序列)并后续因神经根受压行脊柱手术的患者,共39个神经根节段、78个神经根(48个有症状、30个无症状),由两名读者独立对2D、3D(轴位+矢状位)、3D(全部平面)及2D+3D联合进行0至3级分级,采用ROC曲线分析比较诊断性能。
关键影像表现/征象
- 评估对象为后方椎间盘突出、侧隐窝狭窄、神经孔狭窄或椎间孔外椎间盘突出所致的神经根受压。
诊断标准与关键数值
- 神经根受压采用0至3级分级,由两名读者独立评估。
- 读者1的ROC曲线面积:2D+3D联合0.843 vs 2D 0.802,差异有统计学意义(p=0.035)。
- 读者2的ROC曲线面积:2D+3D联合0.820 vs 3D全部平面0.765,差异有统计学意义(p=0.049)。
- 其余影像组间ROC曲线面积差异无统计学意义(p=0.203至>0.999)。
临床应用与阅片要点
- 3D各向同性T2加权TSE序列可单独用于评估腰椎神经根受压,其诊断性能与2D TSE序列无显著差异。
- 联合2D与3D序列可能提高诊断准确率。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To explore the performance of three-dimensional (3D) isotropic T2-weighted turbo spin-echo (TSE) sampling perfection with application optimized contrasts using different flip angle evolution (SPACE) sequence on a 3T system, for the evaluation of nerve root compromise by disc herniation or stenosis from central to extraforaminal location of the lumbar spine, when used alone or in combination with conventional two-dimensional (2D) TSE sequence.
MATERIALS AND METHODS: Thirty-seven patients who had undergone 3T spine MRI including 2D and 3D sequences, and had subsequent spine surgery for nerve root compromise at a total of 39 nerve levels, were analyzed. A total of 78 nerve roots (48 symptomatic and 30 asymptomatic sites) were graded (0 to 3) using different MRI sets of 2D, 3D (axial plus sagittal), 3D (all planes), and combination of 2D and 3D sequences, with respect to the nerve root compromise caused by posterior disc herniations, lateral recess stenoses, neural foraminal stenoses, or extraforaminal disc herniations; grading was done independently by two readers. Diagnostic performance was compared between different imaging sets using the receiver operating characteristics (ROC) curve analysis.
RESULTS: There were no statistically significant differences (p = 0.203 to > 0.999) in the ROC curve area between the imaging sets for both readers 1 and 2, except for combined 2D and 3D (0.843) vs. 2D (0.802) for reader 1 (p = 0.035), and combined 2D and 3D (0.820) vs. 3D including all planes (0.765) for reader 2 (p = 0.049).
CONCLUSION: The performance of 3D isotropic T2-weighted TSE sequence of the lumbar spine, whether axial plus sagittal images, or all planes of images, was not significantly different from that of 2D TSE sequences, for the evaluation of nerve root compromise of the lumbar spine. Combining 2D and 3D might possibly improve the diagnostic accuracy compared with either one.
引用
- Sung J, Jee WH, Jung JY, et al. Diagnosis of Nerve Root Compromise of the Lumbar Spine: Evaluation of the Performance of Three-dimensional Isotropic T2-weighted Turbo Spin-Echo SPACE Sequence at 3T. Korean J Radiol. 2017. PMID: 28096733. doi:10.3348/kjr.2017.18.1.249