剪切波弹性成像是一种可靠且可重复的测量股直肌和髌腱弹性模量的方法
本研究在12名健康男性中评估剪切波弹性成像测量髌腱和股直肌硬度的组内、组间及日间信度。使用9L4探头和Acuson S3000超声系统及Virtual Touch组织成像定量技术测量剪切波速度。髌腱组内和日间信度优秀(ICC 0.91-0.92和0.81-0.83),组间信度良好(ICC 0.71);股直肌组内、日间和组间信度均完美(ICC 0.93-0.94、0.81-0.91和0.95)。结论认为该技术可靠且可重复。
要点
- 髌腱剪切波弹性成像组内信度ICC 0.91-0.92,日间信度ICC 0.81-0.83,组间信度ICC 0.71。
- 股直肌剪切波弹性成像组内信度ICC 0.93-0.94,日间信度ICC 0.81-0.91,组间信度ICC 0.95。
- 使用9L4探头和Virtual Touch组织成像定量技术测量髌腱和股直肌硬度可靠且可重复。
核心结论
- 使用Virtual Touch组织成像定量技术的剪切波弹性成像根据组内、日间和组间ICC值,是测量髌腱和股直肌硬度的可靠且可重复的技术。
研究设计与样本
- 在12名健康男性个体中进行的研究;两名检查者使用9L4(4-9 MHz)探头和Acuson S3000超声系统(Siemens Medical Solutions, Mountain View, CA)测量双侧髌腱和股直肌的平均剪切波速度值;弹性图像通过Virtual Touch组织成像定量技术(Siemens Medical Solutions)获取;首次测量后20分钟和1周重复测量;采用组内相关系数(ICC)评估剪切波弹性成像测量的信度。
诊断标准与关键数值
- 髌腱硬度测量:组内信度ICC 0.91-0.92,日间信度ICC 0.81-0.83,组间信度ICC 0.71。
- 股直肌硬度测量:组内信度ICC 0.93-0.94,日间信度ICC 0.81-0.91,组间信度ICC 0.95。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The purpose of this study was to determine intraobserver, interobserver, and inter-day reliability levels for stiffness measurements of the patellar tendon and rectus femoris muscle using shear wave elastography (SWE).
METHODS: This study was conducted on 12 healthy male individuals. Two examiners measured mean shear wave velocity values of the patellar tendons and rectus femoris muscles of both extremities using a 9L4 (4-9 MHz) transducer and an Acuson S3000 ultrasound system (Siemens Medical Solutions, Mountain View, CA). The elasticity images were acquired by the Virtual Touch tissue imaging quantification technique (Siemens Medical Solutions). Measurements were repeated 20 minutes and 1 week after the first measurements. The reliability of SWE measurements was assessed by means of the intraclass correlation coefficient (ICC).
RESULTS: The 12 participants ranged in age from 19 to 33 years (mean age ± SD, 25.33 ± 4.56 years). For the patellar tendon stiffness measurements with SWE, it was found that intraobserver reliability (ICC, 0.91-0.92) and interday reliability (ICC, 0.81-0.83) were excellent, and interobserver reliability (ICC, 0.71) was good. For the rectus femoris muscle stiffness measurements with SWE, it was found that the intraobserver reliability (ICC, 0.93-0.94), interday reliability (ICC, 0.81-0.91), and interobserver reliability (ICC, 0.95) were perfect.
CONCLUSIONS: Shear wave elastography using the Virtual Touch tissue imaging quantification technique is a reliable and repeatable technique for patellar tendon and rectus femoris stiffness measurements according to intraobserver, interday, and interobserver ICC values.
引用
- Taş S, Onur MR, Yılmaz S, et al. Shear Wave Elastography Is a Reliable and Repeatable Method for Measuring the Elastic Modulus of the Rectus Femoris Muscle and Patellar Tendon. J Ultrasound Med. 2017. PMID: 28108983. doi:10.7863/ultra.16.03032
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。