文献速递乳腺技术与安全US

一种用于实性乳腺肿块评估的剪切波弹性成像定性模式分类新方法

A new qualitative pattern classification of shear wave elastograghy for solid breast mass evaluation.
PubMed 文献 · Eur J Radiol · 2016-12-21

研究纳入2015年4月至2016年3月314例女性325个乳腺肿块,比较新提出的Qual1五色模式分类、既往Qual2四色叠加分类、定量SWE参数及常规超声的诊断效能。以病理为金标准,Qual1的Az值高于Qual2和定量SWE参数(均P<0.05);以Color pattern 1降级、Color pattern 5升级BI-RADS分类时Az值最高(0.951),特异度86.56%(P=0.002)高于常规超声的81.18%,敏感度相同(94.96%)。

要点

  • Qual1将SWE图像分为5种颜色模式:均匀型、较均匀型、不规则异质型、病灶内回声型、硬环征型。
  • 以Color pattern 1降级、Color pattern 5升级BI-RADS分类时Az值最高(0.951),特异度86.56%高于常规超声的81.18%(P=0.002),敏感度相同(94.96%)。
  • Qual1的Az值高于Qual2和定量SWE参数(均P<0.05)。

核心结论

  • 本研究提出的定性分类可能代表SWE参数,并可能作为乳腺肿块诊断的相关辅助手段。

研究设计与样本

  • 前瞻性纳入2015年4月至2016年3月314例连续女性325个乳腺肿块,所有肿块均计划行空心针穿刺活检和/或手术活检,均行常规超声和SWE检查,以病理结果为金标准。

关键影像表现/征象

  • Qual1将SWE图像视觉评估分为5种颜色模式:Color pattern 1(均匀型)、Color pattern 2(较均匀型)、Color pattern 3(不规则异质型)、Color pattern 4(病灶内回声型)、Color pattern 5(硬环征型)。
  • Qual2为既往提出的四色叠加模式分类(Tozaki和Fukuma,Acta Radiologica,2011)。

诊断标准与关键数值

  • 325个乳腺肿块中恶性139个(42.77%),良性186个(57.23%)。
  • Qual1的Az值高于Qual2和定量SWE参数(均P<0.05)。
  • 以Qual1=Color pattern 1降级、Qual1=Color pattern 5升级BI-RADS分类时,Az值最高(0.951),特异度86.56%(P=0.002)高于常规超声的81.18%,敏感度相同(94.96%)。

临床应用与阅片要点

  • 作者认为该定性分类可能代表SWE参数,并可能作为乳腺肿块诊断的相关辅助手段。
  • 以Color pattern 1降级、Color pattern 5升级BI-RADS分类时获得最高Az值(0.951)及高于常规超声的特异度(86.56% vs 81.18%,P=0.002),敏感度相同(94.96%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To examine the efficacy of qualitative shear wave elastography (SWE) in the classification and evaluation of solid breast masses, and to compare this method with conventional ultrasonograghy (US), quantitative SWE parameters and qualitative SWE classification proposed before.

METHODS: From April 2015 to March 2016, 314 consecutive females with 325 breast masses who decided to undergo core needle biopsy and/or surgical biopsy were enrolled. Conventional US and SWE were previously performed in all enrolled subjects. Each mass was classified by two different qualitative classifications. One was established in our study, herein named the Qual1. Qual1 could classify the SWE images into five color patterns by the visual evaluations: Color pattern 1 (homogeneous pattern); Color pattern 2 (comparative homogeneous pattern); Color pattern 3 (irregularly heterogeneous pattern); Color pattern 4 (intralesional echo pattern); and Color pattern 5 (the stiff rim sign pattern). The second qualitative classification was named Qual2 here, and included a four-color overlay pattern classification (Tozaki and Fukuma, Acta Radiologica, 2011). The Breast Imaging Reporting and Data System (BI-RADS) assessment and quantitative SWE parameters were recorded. Diagnostic performances of conventional US, SWE parameters, and combinations of US and SWE parameters were compared.

RESULTS: With pathological results as the gold standard, of the 325 examined breast masses, 139 (42.77%) samples were malignant and 186 (57.23%) were benign. The Qual1 showed a higher Az value than the Qual2 and quantitative SWE parameters (all P<0.05). When applying Qual1=Color pattern 1 for downgrading and Qual1=Color pattern 5 for upgrading the BI-RADS categories, we obtained the highest Az value (0.951), and achieved a significantly higher specificity (86.56%, P=0.002) than that of the US (81.18%) with the same sensitivity (94.96%).

CONCLUSIONS: The qualitative classification proposed in this study may be representative of SWE parameters and has potential to be relevant assistance in breast mass diagnoses.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Cong R, Li J, Guo S, et al. A new qualitative pattern classification of shear wave elastograghy for solid breast mass evaluation. Eur J Radiol. 2016. PMID: 28065370. doi:10.1016/j.ejrad.2016.12.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。