联合应用弹性成像评分与应变比结合B型超声可避免乳腺病灶的不必要活检
该前瞻性研究对130个乳腺病灶行B型超声和应变弹性成像检查,其中117名女性随后接受细针穿刺细胞学/活检。恶性病灶的弹性成像评分中位数(4.5 vs 2.9,p < 0.001)和应变比中位数(4.9 vs 2.3,p < 0.001)均显著高于良性病灶。弹性成像评分(cutoff=3.8)敏感度90.5%、特异度93.2%,应变比(cutoff=3.5)敏感度87.5%、特异度87.6%;弹性成像联合B型超声提高了特异度、准确率和阳性预测值,ROC曲线下面积更高。
要点
- 恶性病灶弹性成像评分中位数4.5 vs 良性2.9(p < 0.001),应变比中位数4.9 vs 2.3(p < 0.001)。
- 弹性成像评分cutoff=3.8时敏感度90.5%、特异度93.2%;应变比cutoff=3.5时敏感度87.5%、特异度87.6%。
- 弹性成像联合B型超声可提高特异度、准确率和阳性预测值,ROC曲线下面积更高。
核心结论
- 联合应用B型超声、弹性成像评分和应变比可提高乳腺病灶的诊断性能,常规使用该诊断算法可减少不必要的活检。
研究设计与样本
- 前瞻性研究,对130个乳腺病灶行B型超声和应变弹性成像检查,其中117名女性随后接受细针穿刺细胞学/活检。
诊断标准与关键数值
- 弹性成像评分cutoff=3.8时,敏感度90.5%、特异度93.2%。
- 应变比cutoff=3.5时,敏感度87.5%、特异度87.6%。
- 恶性病灶弹性成像评分中位数4.5 vs 良性2.9(p < 0.001)。
- 恶性病灶应变比中位数4.9 vs 良性2.3(p < 0.001)。
临床应用与阅片要点
- 弹性成像联合B型超声可提高特异度、准确率和阳性预测值,ROC曲线下面积更高。
- 常规使用该诊断算法可减少不必要的活检。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The aim of this study was to evaluate whether the combination of B-mode ultrasound, elastography score (ES) and strain ratio (SR) improves diagnostic performance with respect to breast lesions. One hundred thirty lesions were prospectively evaluated by B-mode ultrasound and strain elastography, followed by fine-needle aspiration cytology/biopsy in 117 woman who were scheduled for regular breast BUS. The median ES (4.5 vs. 2.9, p < 0.001) and SR (4.9 vs. 2.3, p < 0.001) were significantly higher for malignant than for benign lesions. A sensitivity of 90.5% and specificity of 93.2% for the ES (cutoff point = 3.8) and a sensitivity of 87.5% and specificity of 87.6% for the SR (cutoff point = 3.5) were obtained. Elastography combined with B-mode ultrasound improved the specificity, accuracy and positive predictive value. Receiver operating characteristic curves yielded a higher value for the combined technique for diagnosis of breast lesions. Routine use of such a diagnostic algorithm could reduce the number of unnecessary biopsies.
引用
- Bojanic K, Katavic N, Smolic M, et al. Implementation of Elastography Score and Strain Ratio in Combination with B-Mode Ultrasound Avoids Unnecessary Biopsies of Breast Lesions. Ultrasound Med Biol. 2017. PMID: 28094066. doi:10.1016/j.ultrasmedbio.2016.11.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。