文献速递神经妇产影像US

透明隔腔比值:胎儿胼胝体部分发育不全的标志物

Cavum septi pellucidi (CSP) ratio: a marker for partial agenesis of the fetal corpus callosum.
PubMed 文献 · Ultrasound Obstet Gynecol · 2017-08-09

本研究在323例正常胎儿和20例胼胝体部分发育不全胎儿中测量透明隔腔长度和宽度并计算长宽比,发现正常胎儿透明隔腔比值随双顶径增大而减小,胼胝体部分发育不全胎儿透明隔腔短、宽且比值小(95%小于第5百分位),提示该比值可能识别胼胝体部分发育不全高风险胎儿。

要点

  • 胼胝体部分发育不全胎儿透明隔腔常短而宽,比值减小。
  • 正常胎儿透明隔腔比值随孕周增加而减小,需按双顶径校正。
  • 透明隔腔比值小于第5百分位见于95%胼胝体部分发育不全胎儿。

核心结论

  • 胼胝体大小正常的胎儿透明隔腔呈矩形,妊娠后半期透明隔腔比值大于1.5。
  • 多数胼胝体部分发育不全胎儿透明隔腔形态异常、宽而短,透明隔腔比值减小。
  • 该简单比值有潜力识别胼胝体部分发育不全高风险胎儿。

研究设计与样本

  • 回顾性病例对照研究,纳入323例正常胎儿和20例胼胝体部分发育不全胎儿,孕20至34周。
  • 在胎儿头部轴平面上测量透明隔腔长度和宽度,计算长宽比(透明隔腔比值)。
  • 基于正常人群构建透明隔腔比值与双顶径相关的参考范围,并计算所有胎儿的Z值。

关键影像表现/征象

  • 正常胎儿透明隔腔长度和宽度随双顶径增大而增加,透明隔腔比值随双顶径增大而减小。
  • 胼胝体部分发育不全胎儿中85%(17/20)透明隔腔短(小于第5百分位)。
  • 胼胝体部分发育不全胎儿中65%(13/20)透明隔腔宽(大于第95百分位)。
  • 胼胝体部分发育不全胎儿中95%(19/20)透明隔腔比值小(小于第5百分位),其中16/20(80%)比值低于经验临界值1.5。
  • Z值分析显示胼胝体部分发育不全胎儿透明隔腔比值显著小于正常人群(P < 0.0001)。

诊断标准与关键数值

  • 透明隔腔比值小于第5百分位对胼胝体部分发育不全的检出率为95%(19/20)。
  • 透明隔腔比值低于经验临界值1.5见于80%(16/20)胼胝体部分发育不全胎儿。
  • 正常胎儿妊娠后半期透明隔腔比值大于1.5。

临床应用与阅片要点

  • 在胎儿头部轴平面测量透明隔腔长度和宽度,计算长宽比并按双顶径校正Z值。
  • 注意胼胝体部分发育不全胎儿透明隔腔可表现为短而宽的异常形态,而非缺如。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: While complete agenesis of the corpus callosum is often suspected on fetal ultrasound due to absence of the cavum septi pellucidi (CSP), suspicion of partial agenesis of the corpus callosum (pACC) is a challenge since the CSP is almost always present. The aim of this study was to measure the length and width of the CSP and calculate the length-to-width ratio (CSP ratio), and compare these between fetuses with pACC and normal fetuses.

METHODS: In this retrospective case-control study, the length and width of the CSP were measured in the axial plane of the fetal head, and the CSP length-to-width ratio calculated, in 323 normal fetuses and in 20 fetuses with pACC between 20 and 34 weeks' gestation. From the normal population we constructed reference ranges in relation to biparietal diameter (BPD). For all fetuses we calculated Z-scores for the CSP ratio.

RESULTS: In the normal population, the length and width of the CSP increased with increasing BPD, while the CSP ratio decreased. The CSP was short (< 5th centile) in 85% (17/20) of fetuses with pACC and wide (> 95th centile) in 65% (13/20). The CSP ratio was small (< 5th centile) in 95% (19/20) of pACC fetuses, with 16/20 (80%) having a ratio below an empirical cut-off of 1.5. Analysis of Z-scores showed that fetuses with pACC had a significantly smaller CSP ratio (P < 0.0001) compared with the normal population.

CONCLUSIONS: Fetuses with a normal-sized corpus callosum have a rectangular-shaped CSP, with a CSP ratio > 1.5 in the second half of gestation. Most fetuses with pACC have an abnormally shaped, wide and short CSP, with a decreased CSP ratio. This simple ratio has the potential to identify fetuses at high risk for pACC. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Karl K, Esser T, Heling KS, et al. Cavum septi pellucidi (CSP) ratio: a marker for partial agenesis of the fetal corpus callosum. Ultrasound Obstet Gynecol. 2017. PMID: 28078790. doi:10.1002/uog.17409

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。