正常与不育男性的睾丸剪切波弹性成像:一项601例患者的前瞻性研究
该前瞻性研究评估睾丸剪切波弹性成像在62例正常患者和539例不育男性中的可行性与可重复性,可行性率96.9%,组内相关系数0.85(95%CI 0.83-0.88)。睾丸硬度与睾丸体积呈显著正相关(p=0.001),梗阻性无精子症硬度高于非Klinefelter综合征非梗阻性无精子症(p=1.e-10),Klinefelter综合征非梗阻性无精子症硬度高于非梗阻性无精子症人群(p=2.0e-8),但大量重叠值限制了临床影响。
要点
- 睾丸剪切波弹性成像可行性率96.9%,组内相关系数0.85(95%CI 0.83-0.88),可重复性好。
- 梗阻性无精子症硬度2.4 kPa(2.0, 2.7)高于非Klinefelter综合征非梗阻性无精子症2.0 kPa(1.7, 2.4)(p=1.e-10)。
- Klinefelter综合征非梗阻性无精子症硬度2.6 kPa(2, 3.2)高于非梗阻性无精子症人群(p=2.0e-8)。
核心结论
- 睾丸剪切波弹性成像是一项可行且可重复的技术;睾丸硬度与睾丸体积呈显著正相关(p=0.001);梗阻性无精子症硬度高于非Klinefelter综合征非梗阻性无精子症(p=1.e-10),Klinefelter综合征非梗阻性无精子症硬度高于非梗阻性无精子症人群(p=2.0e-8),但大量重叠值限制了其临床影响。
研究设计与样本
- 前瞻性研究,纳入62例正常患者和539例不育男性,共601例患者;按临床分类分为正常睾丸(n=108)、少弱畸精子症(n=689)、梗阻性无精子症(n=119)、非Klinefelter综合征非梗阻性无精子症(n=183)、Klinefelter综合征非梗阻性无精子症(n=70)和左侧精索静脉曲张(n=132)组;评估睾丸剪切波弹性成像的可行性与可重复性。
关键影像表现/征象
- 正常睾丸中位硬度(四分位距)为2.4 kPa(2.0, 2.9)。
- 少弱畸精子症中位硬度(四分位距)为2.1 kPa(1.8, 2.5)。
- 梗阻性无精子症中位硬度(四分位距)为2.4 kPa(2.0, 2.7)。
- 非Klinefelter综合征非梗阻性无精子症中位硬度(四分位距)为2.0 kPa(1.7, 2.4)。
- Klinefelter综合征非梗阻性无精子症中位硬度(四分位距)为2.6 kPa(2, 3.2)。
诊断标准与关键数值
- 可行性率为96.9%。
- 组内相关系数为0.85(95%置信区间:0.83-0.88)。
- 睾丸硬度与睾丸体积呈显著正相关(p=0.001)。
- 梗阻性无精子症硬度高于非Klinefelter综合征非梗阻性无精子症(p=1.e-10)。
- Klinefelter综合征非梗阻性无精子症硬度高于非梗阻性无精子症人群(p=2.0e-8)。
临床应用与阅片要点
- 睾丸剪切波弹性成像可用于评估睾丸硬度,可行性及可重复性良好。
- 不同病因组间硬度值存在大量重叠,可能限制其临床鉴别价值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Our aim in the study described here was to prospectively establish the feasibility of using and reproducibility of testicular shear-wave elastography in the assessment of testicular stiffness in 62 normal patients and 539 infertile men with obstructive azoospermia (OA), non-Klinefelter syndrome non-obstructive azoospermia (non-KS NOA), Klinefelter syndrome NOA (KS NOA), oligoasthenoteratozoospermia (OAT) or a left varicocele. The feasibility rate was 96.9%, with an intra-class correlation coefficient of 0.85 (95% confidence interval: 0.83-0.88). Median stiffness (interquartile range) values were 2.4 kPa (2.0, 2.9), 2.1 kPa (1.8, 2.5), 2.4 kPa (2.0, 2.7), 2.0 kPa (1.7, 2.4), 2.6 kPa (2, 3.2) and 2.2 kPa (1.8, 2.6) for men with a normal testis (n = 108), OAT (n = 689), OA (n = 119), non-KS NOA (n = 183), KS NOA (n = 70) and varicocele (n = 132), respectively. Testicular shear wave elastography is a feasible and reproducible technique. A significant positive association was found between stiffness and testis volume (p = 0.001). Testicular stiffness was higher in OA than in non-KS NOA populations (p = 1.e-10) and in KS NOA than in NOA populations (p = 2.0e-8), but the substantial number of overlapping values limited the clinical impact.
引用
- Rocher L, Criton A, Gennisson JL, et al. Testicular Shear Wave Elastography in Normal and Infertile Men: A Prospective Study on 601 Patients. Ultrasound Med Biol. 2017. PMID: 28062178. doi:10.1016/j.ultrasmedbio.2016.11.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。