定量肿瘤灌注参数在患者个体内变异性和可重复性的动态对比增强超声研究
这项前瞻性单中心研究在真实临床条件下评估动态对比增强超声(DCE-US)参数的个体内变异性和可重复性。60例接受抗血管生成治疗的患者在基线、第15天和治疗后1个月分别进行餐前和餐后DCE-US检查,共分析128对检查。结果显示餐前与餐后值无显著差异,曲线下面积和洗脱曲线下面积是最可重复的两个DCE-US参数(相关系数0.89,个体内变异系数分别为61%和64%)。
要点
- 曲线下面积和洗脱曲线下面积是重复性最好的DCE-US灌注参数,餐前餐后相关系数均为0.89。
- 餐前与餐后DCE-US各参数值无显著差异,个体内变异独立于转移部位。
- 曲线下面积和洗脱曲线下面积的个体内变异系数分别为61%和64%。
核心结论
- 曲线下面积和洗脱曲线下面积是重复性最好的两个DCE-US参数。
研究设计与样本
- 前瞻性单中心研究,纳入60例接受抗血管生成治疗的患者,在基线、第15天和治疗后1个月各行餐前和餐后两次DCE-US检查,注射Sonovue后记录灌注曲线以确定7个灌注参数,共分析128对DCE-US检查(基线45对、第15天45对、1个月38对)。
诊断标准与关键数值
- 曲线下面积和洗脱曲线下面积的餐前与餐后相关系数均为0.89,对应的个体内变异系数分别为61%和64%。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Dynamic contrast-enhanced (DCE) ultrasonography (US) is a functional imaging technique enabling quantitative assessment of solid tumor perfusion in metastatic patients treated with antiangiogenic therapies.The objective of this prospective single-center study was to evaluate in real-life conditions (in routine clinical practice) the intrapatient variability and reproducibility of DCE-US parameters.
MATERIALS AND METHODS: Each patient provided written informed consent and had 2 DCE-US examinations (preprandial and postprandial) at baseline, day 15, and 1 month after treatment initiation. Perfusion curves were recorded after Sonovue injections to determine 7 perfusion parameters. Dynamic contrast-enhanced US examinations were analyzed in pairs: preprandial and postprandial. Log transformed values were used to determine the variability of the pairs (within-subject coefficient of variation) and their reproducibility (Spearman correlation coefficient).
RESULTS: We included 60 patients (23 colon cancers, 36 kidney cancers, and 1 breast cancer) treated with axitinib (26 patients), sunitinib (27 patients), and other antiangiogenic treatments (7 patients). The 60 patients included 38 men (63%) and 22 women (37%) with a median age of 62 (range, 25-82 years). Thirty patients had hepatic and 30 had extrahepatic target lesions. Data were analyzed for 128 pairs of DCE-US: 45 (baseline), 45 (day 15), and 38 (1 month). Preprandial and postprandial values were not significantly different. For area under the curve and area under the washout, the correlation coefficient between preprandial and postprandial values was 0.89; the associated within-subject coefficients of variation were 61% and 64%, respectively. However, the range of individual variations (postprandial value/preprandial value) was less than 2 logs for a range of parameter values of about 4 logs. Variability was independent of the metastatic site.
CONCLUSIONS: This study showed that area under the curve and area under the washout are the 2 most reproducible DCE-US parameters.
引用
- Lassau N, Coiffier B, Faivre L, et al. Study of Intrapatient Variability and Reproducibility of Quantitative Tumor Perfusion Parameters Evaluated With Dynamic Contrast-Enhanced Ultrasonography. Invest Radiol. 2017. PMID: 28106614. doi:10.1097/RLI.0000000000000324
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。