文献速递腹部技术与安全CT

副脾与淋巴结的鉴别:双能CT碘定量的价值

Accessory spleen versus lymph node: Value of iodine quantification with dual-energy computed tomography.
PubMed 文献 · Eur J Radiol · 2016-12-06

回顾性评估75例患者(副脾35例、淋巴结48例)的腹部双能CT图像,测量HU和碘浓度。副脾CT值(148±29 HU)和碘浓度(48.2±11×100μg/cc)均高于淋巴结(83±19 HU、31.5±6.2×100μg/cc,均P<0.001);碘浓度>38×100μg/cc提示副脾,敏感度91%、特异度85%、准确率88%,AUC 0.941。

要点

  • 副脾碘浓度(48.2±11×100μg/cc)高于淋巴结(31.5±6.2×100μg/cc),P<0.001。
  • 碘浓度>38×100μg/cc提示副脾,敏感度91%、特异度85%、准确率88%,AUC 0.941。
  • 副脾碘浓度与主脾(47.7±10×100μg/cc)无显著差异(P=0.095),而CT值低于主脾(161±29 HU,P<0.01)。

核心结论

  • 碘定量可能有助于鉴别副脾与淋巴结,碘浓度与主脾相似可能帮助确认副脾诊断。

研究设计与样本

  • 回顾性评估75例患者(副脾35例、淋巴结48例)的腹部双能CT图像,测量副脾、淋巴结和主脾的HU及碘浓度,用ROC计算鉴别副脾与淋巴结的最佳阈值。

关键影像表现/征象

  • 副脾平均CT值148±29 HU,高于淋巴结83±19 HU(P<0.001)。
  • 副脾平均碘浓度48.2±11×100μg/cc,高于淋巴结31.5±6.2×100μg/cc(P<0.001)。
  • 副脾平均CT值低于主脾161±29 HU(P<0.01),而碘浓度与主脾47.7±10×100μg/cc无显著差异(P=0.095)。

诊断标准与关键数值

  • 碘浓度>38×100μg/cc提示副脾,敏感度91%、特异度85%、准确率88%,AUC 0.941。

临床应用与阅片要点

  • 测量碘浓度可能有助于鉴别副脾与淋巴结,碘浓度与主脾相似可能帮助确认副脾诊断。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate whether iodine quantification with Dual-Energy Computed Tomography (DECT) improves the differentiation of accessory spleens (AS) from lymph nodes (LN) compared to CT number measurements.

METHODS: Abdominal DECT images of 75 patients with either AS (n=35) or LN (n=48) (benign entity) were retrospectively evaluated. Hounsfield Units (HU) and iodine concentrations of AS, LN and the main spleen were measured. Receiver operating characteristics (ROC) were performed to calculate an optimal threshold for distinguishing AS from LN. Sensitivity, specificity, and accuracy were calculated for distinguishing AS from LN by iodine concentration measurements.

RESULTS: Mean CT numbers and iodine concentrations were higher for AS (148±29 HU and 48.2±11×100μg/cc) than LN (83±19 HU and 31.5±6.2×100μg/cc, respectively, P<0.001 each). Mean CT numbers were lower for AS compared to the main spleen (161±29HU, P<0.01), whereas mean iodine concentrations (47.7±10×100μg/cc) were not significantly different (P=0.095). An iodine concentration greater than 38×100μg/cc suggested AS with a sensitivity, specificity and accuracy of 91%, 85%, and 88%, respectively (Area under ROC curve 0.941).

CONCLUSIONS: Iodine measurements might contribute to the differentiation of AS from LN. Iodine concentrations similar to that of the main spleen may help to confirm the diagnosis of AS.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Winklhofer S, Lin WC, Lambert JW, et al. Accessory spleen versus lymph node: Value of iodine quantification with dual-energy computed tomography. Eur J Radiol. 2016. PMID: 28065375. doi:10.1016/j.ejrad.2016.12.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。