验证一种半自动技术使用CT和MRI准确测量腹部脂肪分布以进行临床风险分层
本研究在单中心回顾性识别15例乳房重建术后患者共30次CT和MRI扫描,于L3椎体水平用免费软件半自动量化腹部脂肪分布,观察者内和观察者间Pearson R分别为0.954-1.00和0.799-0.999,两种模态间Pearson R为0.625-0.903,并给出互换的数学归一化模型。
要点
- 半自动腹部脂肪分布测量在观察者内和观察者间均高度可重复。
- CT与MRI测得的腹部脂肪分布值间存在强可互换关系,与两次检查间隔时间无关。
- 该方法可用于非顺序扫描和非研究场景,结果可直接比较。
核心结论
- 所描述方法高度可重复且独立于评分者偏倚,回顾性CT和MRI计算的腹部脂肪分布间存在强可互换关系。
研究设计与样本
- 单中心回顾性研究,连续识别15例乳房重建术后患者共30次CT和MRI扫描,由至少两名独立操作者使用免费软件于L3椎体水平量化腹部脂肪分布,采用Bland-Altman图评估观察者内和观察者间差异,Pearson相关验证模态间数据,线性回归分析建立模态间数学归一化模型。
诊断标准与关键数值
- 观察者内Pearson R为0.954-1.00,观察者间Pearson R为0.799-0.999。
- CT与MRI间Pearson R为0.625-0.903,且独立于两次成像间隔时间。
临床应用与阅片要点
- 该方法可用于前瞻性风险分层,尤其适用于接受重建乳房手术的患者。
- 分析为半自动,结果可直接比较,不受成像模态或患者体位影响。
- 该方法预期可应用于许多其他临床专科。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: A valid method for accurate quantification of abdominal fat distribution (AFD) using both CT and MRI is described. This method will be primarily useful in the prospective risk stratification of patients undergoing reconstructive breast surgery. Secondary applications in many other clinical specialities are foreseen.
METHODS: 15 sequential patients who had undergone breast reconstruction following both CT and MRI (30 scans) were retrospectively identified at our single centre. The AFD was quantified at the level of the L3 vertebra. Image analysis was performed by at least two independent operators using free software. Intra- and interobserver differences were assessed using Bland-Altman plots. Data were validated between imaging modalities by Pearson's correlation. Linear regression analyses were used to mathematically normalize results between imaging modalities.
RESULTS: The method was statistically independent of rater bias (intra: Pearson's R-0.954-1.00; inter: 0.799-0.999). Strong relationships between imaging modalities were demonstrated and are independent of time between imaging (Pearson's R 0.625-0.903). Interchangeable mathematical models to normalize between imaging modality are shown.
CONCLUSION: The method described is highly reproducible and independent of rater bias. A strong interchangeable relationship exists between calculations of AFD on retrospective CT and MRI. Advances in knowledge: This is the first technique to be applicable to scans that are not performed sequentially or in a research setting. Analysis is semi-automated and results can be compared directly, regardless of imaging modality or patient position. This method has clinical utility in prospective risk stratification and will be applicable to many clinical specialities.
引用
- Waduud MA, Sharaf A, Roy I, et al. Validation of a semi-automated technique to accurately measure abdominal fat distribution using CT and MRI for clinical risk stratification. Br J Radiol. 2017. PMID: 28055246. doi:10.1259/bjr.20160662