文献速递介入腹部US

新型射频装置减少粗针活检后出血:猪肝模型实验研究

New Radiofrequency Device to Reduce Bleeding after Core Needle Biopsy: Experimental Study in a Porcine Liver Model.
PubMed 文献 · Korean J Radiol · 2017-01-05

在猪肝模型上评估活检道射频消融对粗针活检后止血的效率,包括出血倾向和使用较大(16G)粗针的情况。初步研究确定最佳消融参数后,四只猪按肝素化和针径分组,每组进行14次对照和14次实验性超声引导活检,测量5分钟出血量。所有实验组出血量均小于对照组,但在非肝素化18G针和两只肝素化猪中差异显著(p < 0.001)。

要点

  • 活检道射频消融参数为2 cm活性尖端电极、40瓦、尖端温度70-80℃。
  • 肝素化猪中,实验组平均失血量分别为18G和16G针对照组的3.5%和13.5%。
  • 所有实验组出血量均小于对照组,但仅在部分组中差异显著(p < 0.001)。

核心结论

  • 根据猪体内模型实验结果,肝活检道射频消融可能减少活检后出血,即使在出血倾向和使用较大粗针的情况下。

研究设计与样本

  • 实验研究,使用五只猪(一只初步研究,四只主要实验),主要实验中每只猪进行14次对照和14次实验性超声引导肝活检,按肝素化使用和活检针径(18G或16G)分组。

诊断标准与关键数值

  • 最佳活检道消融参数为2 cm活性尖端电极、40瓦、尖端温度70-80℃。
  • 肝素化猪中,实验组平均失血量分别为18G针对照组的3.5%和16G针对照组的13.5%。
  • 非肝素化18G针和两只肝素化猪中,实验组与对照组出血量差异显著(p < 0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the in vivo efficiency of the biopsy tract radiofrequency ablation for hemostasis after core biopsy of the liver in a porcine liver model, including situations with bleeding tendency and a larger (16-gauge) core needle.

MATERIALS AND METHODS: A preliminary study was performed using one pig to determine optimal ablation parameters. For the main experiment, four pigs were assigned to different groups according to heparinization use and biopsy needle caliber. In each pig, 14 control (without tract ablation) and 14 experimental (tract ablation) ultrasound-guided core biopsies were performed using either an 18- or 16-gauge needle. Post-biopsy bleeding amounts were measured by soaking up the blood for five minutes. The results were compared using the Mann-Whitney U test.

RESULTS: The optimal parameters for biopsy tract ablation were determined as a 2-cm active tip electrode set at 40-watt with a tip temperature of 70-80℃. The bleeding amounts in all experimental groups were smaller than those in the controls; however they were significant in the non-heparinized pig biopsied with an 18-gauge needle and in two heparinized pigs (p < 0.001). In the heparinized pigs, the mean blood loss in the experimental group was 3.5% and 13.5% of the controls biopsied with an 18- and 16-gauge needle, respectively.

CONCLUSION: Radiofrequency ablation of hepatic core biopsy tract ablation may reduce post-biopsy bleeding even under bleeding tendency and using a larger core needle, according to the result from in vivo porcine model experiments.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Lim S, Rhim H, Lee MW, et al. New Radiofrequency Device to Reduce Bleeding after Core Needle Biopsy: Experimental Study in a Porcine Liver Model. Korean J Radiol. 2017. PMID: 28096727. doi:10.3348/kjr.2017.18.1.173

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。