文献速递腹部技术与安全CT

急性腹痛患者急诊评估:迭代重建低剂量CT的对比研究

Emergency assessment of patients with acute abdominal pain using low-dose CT with iterative reconstruction: a comparative study.
PubMed 文献 · Eur Radiol · 2017-01-12

纳入151例需行增强CT的急性腹痛患者,增强CT后立即行低剂量CT,分别用40%迭代重建联合滤波反投影(LDCT-IR-FBP)和基于模型的迭代重建(LDCT-MBIR)处理,两位放射科医生独立阅片。增强CT显示120例(79%)有腹部病变。BMI<30患者中LDCT-MBIR准确率最高达99%-100%,BMI≥30患者中LDCT-MBIR准确率为90.5%-92.9%。结论认为LDCT-MBIR可将非肥胖急性腹痛患者的CT辐射剂量降至接近标准X线摄影的水平。

要点

  • LDCT-MBIR(<2.5 mSv)可用于评估急性腹痛。
  • LDCT-MBIR(<2.5 mSv)不能安全评估肥胖患者的急性腹痛。
  • LDCT-IR-FBP(<2.5 mSv)不能安全评估急性腹痛患者。

核心结论

  • LDCT-MBIR可将非肥胖急性腹痛患者的CT辐射剂量安全降至接近标准X线摄影的水平(<2.5 mSv);LDCT-MBIR不能安全评估肥胖患者的急性腹痛,LDCT-IR-FBP不能安全评估急性腹痛患者。

研究设计与样本

  • 对比研究,连续纳入151例需行增强CT评估急性腹痛的患者并计算BMI,增强CT后立即行低剂量CT,低剂量序列分别经40%迭代重建联合滤波反投影(LDCT-IR-FBP)和基于模型的迭代重建(LDCT-MBIR)处理,由两位委员会认证的放射科医生独立阅片,以增强CT为参考标准。

诊断标准与关键数值

  • BMI<30患者中,Reader 1以增强CT为参考,LDCT-IR-FBP诊断准确率为95.4%(104/109),LDCT-MBIR为99%(108/109)。
  • BMI<30患者中,Reader 2以增强CT为参考,LDCT-IR-FBP诊断准确率为92.7%(101/109),LDCT-MBIR为100%(109/109)。
  • BMI≥30患者中,Reader 1的LDCT-IR-FBP诊断准确率为88.1%(37/42),LDCT-MBIR为90.5%(38/42)。
  • BMI≥30患者中,Reader 2的LDCT-IR-FBP诊断准确率为78.6%(33/42),LDCT-MBIR为92.9%(39/42)。
  • 增强CT在120例(79%)患者中显示腹部病变。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine if radiation dose delivered by contrast-enhanced CT (CECT) for acute abdominal pain can be reduced to the dose administered in abdominal radiography (<2.5 mSv) using low-dose CT (LDCT) with iterative reconstruction algorithms.

METHODS: One hundred and fifty-one consecutive patients requiring CECT for acute abdominal pain were included, and their body mass index (BMI) was calculated. CECT was immediately followed by LDCT. LDCT series was processed using 1) 40% iterative reconstruction algorithm blended with filtered back projection (LDCT-IR-FBP) and 2) model-based iterative reconstruction algorithm (LDCT-MBIR). LDCT-IR-FBP and LDCT-MBIR images were reviewed independently by two board-certified radiologists (Raters 1 and 2).

RESULTS: Abdominal pathology was revealed on CECT in 120 (79%) patients. In those with BMI <30, accuracies for correct diagnosis by Rater 1 with LDCT-IR-FBP and LDCT-MBIR, when compared to CECT, were 95.4% (104/109) and 99% (108/109), respectively, and 92.7% (101/109) and 100% (109/109) for Rater 2. In patients with BMI ≥30, accuracies with LDCT-IR-FBP and LDCT-MBIR were 88.1% (37/42) and 90.5% (38/42) for Rater 1 and 78.6% (33/42) and 92.9% (39/42) for Rater 2.

CONCLUSIONS: The radiation dose delivered by CT to non-obese patients with acute abdominal pain can be safely reduced to levels close to standard radiography using LDCT-MBIR.

KEY POINTS: • LDCT-MBIR (<2.5 mSv) can be used to assess acute abdominal pain. • LDCT-MBIR (<2.5 mSv) cannot safely assess acute abdominal pain in obese patients. • LDCT-IR-FBP (<2.5 mSv) cannot safely assess patients with acute abdominal pain.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Poletti PA, Becker M, Becker CD, et al. Emergency assessment of patients with acute abdominal pain using low-dose CT with iterative reconstruction: a comparative study. Eur Radiol. 2017. PMID: 28083698. doi:10.1007/s00330-016-4712-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。