肝细胞癌的扩散加权成像(DWI):定性与定量DWI与肿瘤分级相关性的回顾性分析
DWI的定性及定量信号强度值和ADC值可能有助于术前无创评估肝细胞癌的组织学分级。
要点
- ADC值在高、中、低分化肝细胞癌间两两均有显著差异,均值分别为1.67±0.13×10⁻³、1.31±0.16×10⁻³、1.08±0.11×10⁻³ mm²/s。
- ADC值诊断高分化与低分化肝细胞癌的最佳操作点分别为1.5×10⁻³和1.24×10⁻³ mm²/s。
- 信号强度值预测高分化肝细胞癌的最佳操作点为66.5,但中分化与低分化之间信号强度值无显著差异。
核心结论
- DWI的定性及定量信号强度值和ADC值可能有助于术前无创评估肝细胞癌的组织学分级。
关键影像表现/征象
- 肉眼信号强度与组织学分级呈弱负相关(r=-0.350,p<0.05)。
- 高分化肝细胞癌平均信号强度值为68.32±31.71,中分化为102.39±45.55,低分化为114.55±32.15;高分化与中分化/低分化之间差异显著,中分化与低分化之间无显著差异。
- 高、中、低分化肝细胞癌平均ADC值分别为1.67±0.13×10⁻³、1.31±0.16×10⁻³、1.08±0.11×10⁻³ mm²/s,任意两组间差异均显著。
诊断标准与关键数值
- 信号强度值预测高分化肝细胞癌的最佳操作点为66.5(ROC曲线分析)。
- ADC值诊断高分化肝细胞癌的最佳操作点为1.5×10⁻³ mm²/s。
- ADC值诊断低分化肝细胞癌的最佳操作点为1.24×10⁻³ mm²/s。
临床应用与阅片要点
- 阅片时可结合DWI肉眼信号强度、信号强度值及ADC值综合评估肝细胞癌的可能组织学分级。
- ADC值1.5×10⁻³ mm²/s和1.24×10⁻³ mm²/s分别可作为提示高分化与低分化肝细胞癌的参考操作点。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the application of qualitative and quantitative diffusion-weighted imaging (DWI) in predicting the histological grade of hepatocellular carcinoma (HCC).
MATERIALS AND METHODS: Two hundred and fifty-four patients with pathologically confirmed HCC who underwent hepatic DWI on a 1.5-T platform (b = 0, 600 s/mm2) were evaluated retrospectively. HCCs were divided into well-, moderately, and poorly differentiated groups. The relationships between naked-eye signal intensity (SI), SI values, apparent diffusion coefficient (ADC) values on DWI, and the histopathological differentiation of HCC were analysed. Receiver operating characteristic (ROC) curves were drawn to determine the optimal operating points (OOPs) of the SI and ADC values to predict the tumour grade.
RESULTS: A weak negative correlation (r=-0.350, p<0.05) was obtained between naked-eye SI and histological grade. There was a significant difference in mean SI values between well- (68.32±31.71) and moderately (102.39±45.55)/poorly (114.55±32.15) differentiated HCC but not between moderately and poorly differentiated HCC. The OOP of the SI value by ROC curve analysis was 66.5 to predict well-differentiated HCC. The mean ADC values of well-, moderately, and poorly differentiated HCC were 1.67±0.13×10-3, 1.31±0.16×10-3, and 1.08±0.11×10-3 mm2/s, respectively, with significant differences between any two combinations of groups. The OOPs of ADC to diagnose well- and poorly differentiated HCC were 1.5×10-3 and 1.24×10-3 mm2/s, respectively.
CONCLUSION: Qualitative and quantitative SI and ADC values at DWI may be useful to estimate the histological grade of HCC preoperatively and non-invasively.
引用
- Jiang T, Xu JH, Zou Y, et al. Diffusion-weighted imaging (DWI) of hepatocellular carcinomas: a retrospective analysis of the correlation between qualitative and quantitative DWI and tumour grade. Clin Radiol. 2017. PMID: 28109531. doi:10.1016/j.crad.2016.12.017