文献速递腹部MR

MRI可同时准确量化弥漫性肝病中的肝脂肪变性与铁过载

Accurate simultaneous quantification of liver steatosis and iron overload in diffuse liver diseases with MRI.
PubMed 文献 · Abdom Radiol (NY) · 2017-01-01

研究以活检为参考标准,评估3T多回波化学位移编码梯度回波磁共振(MECSE-MR)在109例成人弥漫性肝病中同时量化肝脂肪变性与铁过载的诊断效能。结果显示,脂肪分数在各脂肪变分级间差异显著(p<0.001),且不受炎症或纤维化影响(p≥0.05);R2*与铁分级强相关(R S = 0.704,p<0.001),除严重铁过载(4级)外铁沉积不影响脂肪分数定量(p≥0.05)。结论认为该序列可在单次屏气内同时量化肝脂肪变性与铁沉着,在广泛弥漫性肝病中具有高准确性。

要点

  • MECSE-MR可在单次屏气内同时量化肝脂肪分数与铁含量(R2*)。
  • 脂肪分数在各脂肪变分级间差异显著(p<0.001),且不受炎症或纤维化影响(p≥0.05)。
  • 除严重铁过载(4级)外,铁沉积不影响脂肪分数定量(p≥0.05)。

核心结论

  • MECSE-MR序列可同时量化肝脂肪变性与铁沉着,不受共存肝脏炎症或纤维化影响,在广泛弥漫性肝病中具有高准确性,可在单次屏气内采集并用于常规肝脏MR评估。

研究设计与样本

  • 以活检为参考标准,前瞻性评估3 Tesla多回波化学位移编码梯度回波磁共振(MECSE-MR)在109例成人弥漫性肝病患者中同时量化肝脂肪变性与铁过载的诊断效能;采用基于复数数据重建与多峰脂肪建模的前瞻性质子密度脂肪分数(PDFF)估计,以水R2*估计铁含量;所有病例均行活检,对肝脂肪变、铁沉着、炎症和纤维化进行分级。

诊断标准与关键数值

  • 脂肪分数测量在各脂肪变分级间差异显著(p<0.001),与脂肪变分级强相关(R S = 0.718,p<0.001);R2*测量与铁分级强正相关(R S = 0.704,p<0.001);ROC曲线分析评估MR诊断性能(原文未报告具体敏感度、特异度、AUC或阈值)。

临床应用与阅片要点

  • 作者结论认为该序列可在单次屏气内采集,并可纳入常规肝脏MR评估;除严重铁过载(4级)外,铁沉积不影响脂肪分数定量(p≥0.05),脂肪分数不受炎症或纤维化影响(p≥0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the diagnostic performances of 3 Tesla multi-echo chemical shift-encoded gradient echo magnetic resonance (MECSE-MR) imaging to simultaneously quantify liver steatosis and iron overload in a wide spectrum of diffuse liver diseases having biopsy as reference standard.

METHODS: MECSE-MR-acquired images were used to calculate fat fraction and iron content in a single breath-hold in 109 adult patients. Proton density fat fraction (PDFF) was prospectively estimated using complex-based data reconstruction with multipeak fat modeling. Water R2* was used to estimate iron content. Biopsy was obtained in all cases, grading liver steatosis, siderosis, inflammation, and fibrosis. Differences in PDFF and R2* values across histopathological grades were analyzed, and ROC curves analyses evaluated the MR diagnostic performance.

RESULTS: Calculated fat fraction measurements showed significant differences (p < 0.001) among steatosis grades, being unaffected by the presence of inflammation or fibrosis (p ≥ 0.05). A strong correlation was found between fat fraction and steatosis grade (R S = 0.718, p < 0.001). Iron deposits did not affect fat fraction quantitation (p ≥ 0.05), except in cases with severe iron overload (grade 4). A strong positive correlation was also observed between R2* measurements and iron grades (R S = 0.704, p < 0.001). Calculated R2* values were not different across grades of steatosis, inflammation, and fibrosis (p ≥ 0.05).

CONCLUSION: A MECSE-MR sequence simultaneously quantifies liver steatosis and siderosis, regardless coexisting liver inflammation or fibrosis, with high accuracy in a wide spectrum of diffuse liver disorders. This sequence can be acquired within a single breath-hold and can be implemented in the routine MR evaluation of the liver.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. França M, Alberich-Bayarri Á, Martí-Bonmatí L, et al. Accurate simultaneous quantification of liver steatosis and iron overload in diffuse liver diseases with MRI. Abdom Radiol (NY). 2017. PMID: 28110367. doi:10.1007/s00261-017-1048-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。