经腹超声诊断慢性胰腺炎的诊断准确性
前瞻性纳入134例疑似慢性胰腺炎患者,54例最终诊断为慢性胰腺炎,评估现代经腹超声以Mayo评分为参考标准的诊断准确性。未加权特征计数敏感度0.69(95%CI 0.54-0.80)、特异度0.97(95%CI 0.90-1),Rosemont评分敏感度0.81(95%CI 0.69-0.91)、特异度0.97(95%CI 0.90-1)。作者结论认为现代经腹超声使用未加权和加权评分诊断准确性均良好,超声所见胰腺改变程度与外分泌功能相关。
要点
- Rosemont评分诊断慢性胰腺炎敏感度0.81(95%CI 0.69-0.91)、特异度0.97(95%CI 0.90-1)。
- 未加权特征计数敏感度0.69(95%CI 0.54-0.80)、特异度0.97(95%CI 0.90-1)。
- 超声所见胰腺改变程度与外分泌功能相关,外分泌功能不全在Rosemont I和II组最明显(p<0.001)。
核心结论
- 使用未加权和加权评分,现代经腹超声诊断慢性胰腺炎的准确性均良好,超声检出的胰腺改变程度与外分泌胰腺功能相关。
研究设计与样本
- 前瞻性研究,纳入134例疑似慢性胰腺炎患者,其中54例最终诊断为慢性胰腺炎,以Mayo评分为参考标准,评估经腹超声的诊断准确性。
关键影像表现/征象
- 记录导管特征:结石、扩张及管径变化、分支导管扩张、管壁高回声边缘。
- 记录实质特征:钙化、囊肿、高回声灶、条索状回声、分叶状改变、蜂窝状改变。
诊断标准与关键数值
- 未加权特征计数:敏感度0.69(95%CI 0.54-0.80),特异度0.97(95%CI 0.90-1)。
- 按Rosemont国际共识会议加权系统计算的Rosemont评分:敏感度0.81(95%CI 0.69-0.91),特异度0.97(95%CI 0.90-1)。
临床应用与阅片要点
- 阅片时应系统记录导管特征(结石、扩张及管径变化、分支导管扩张、管壁高回声边缘)和实质特征(钙化、囊肿、高回声灶、条索状回声、分叶状、蜂窝状)。
- 可按Rosemont评分对特征进行加权计数以提高诊断敏感度。
- 超声所见胰腺改变程度可提示外分泌功能受损,外分泌功能不全在Rosemont I和II组最明显(p<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The performance of transabdominal ultrasound (US) in chronic pancreatitis (CP) following the advances in US technology made during recent decades has not been explored. Our aim in this prospective study was to evaluate the diagnostic accuracy of modern abdominal US compared with the Mayo score in CP. One hundred thirty-four patients referred for suspected CP were included in the study. Fifty-four patients were assigned the diagnosis CP. After inclusion, transabdominal US was performed. Ductal features (calculi, dilations and caliber variations, side-branch dilations and hyper-echoic duct wall margins) and parenchymal features (calcifications, cysts, hyper-echoic foci, stranding, lobulation and honeycombing) were recorded. Features were counted and scored according to a weighting system defined at the international consensus meeting in Rosemont, Illinois (Rosemont score). Diagnostic performance indices (95% confidence interval) of US were calculated: The unweighted count of features had a sensitivity of 0.69 (0.54-0.80) and specificity of 0.97 (0.90-1). The Rosemont score had a sensitivity of 0.81 (0.69-0.91) and specificity of 0.97 (0.90-1). Exocrine pancreatic failure was most pronounced in Rosemont groups I and II (p < 0.001). We conclude that using both unweighted and weighted scores, the diagnostic accuracy of modern transabdominal US is good. The extent of pancreatic changes detected by the method is correlated with exocrine pancreatic function.
引用
- Engjom T, Sangnes DA, Havre RF, et al. Diagnostic Accuracy of Transabdominal Ultrasound in Chronic Pancreatitis. Ultrasound Med Biol. 2017. PMID: 28108042. doi:10.1016/j.ultrasmedbio.2016.11.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。