文献速递腹部技术与安全CT

如何将双能成像整合到高容量腹部影像实践中

"How to" incorporate dual-energy imaging into a high volume abdominal imaging practice.
PubMed 文献 · Abdom Radiol (NY) · 2017-01-01

本文以胰腺多期扫描方案为例,综述快速切换和双源双能平台上双能CT方案的创建方法、高效生成双能图像的不同途径,以及在阅片工作站浏览和使用双能图像的方法,并回顾最常用的三类双能图像。

要点

  • 双能CT方案需根据所用双能扫描技术制定,不同平台要求不同。
  • 常用双能图像包括「主力」120kVp替代图像、高对比图像和虚拟平扫图像。
  • 高容量实践成功实施双能CT需关注扫描、图像生成和图像解读各步骤。

核心结论

  • 在高容量实践中成功实施双能CT需要仔细关注扫描、图像生成和图像解读的每一步。

研究设计与样本

  • 本文为综述,针对快速切换和双源双能平台,以胰腺多期扫描方案为例介绍双能CT协议创建、图像生成和阅片方法。

关键影像表现/征象

  • 双能CT可生成多种新类型图像,增加图像生成和解读的复杂性。

诊断标准与关键数值

  • 「主力」120kVp替代图像包括混合多色图像和70 keV单色图像。
  • 高对比图像包括低能量单色图像和碘物质分解图像。
  • 虚拟平扫图像为三类常用双能图像之一。
  • 双源双能CT平台可在扫描仪上自动生成新的「Mono+」图像。

临床应用与阅片要点

  • 可使用自动化「挂片协议」进行图像解读。
  • 双能协议创建需根据所采用的双能扫描技术制定。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Dual-energy CT imaging has many potential uses in abdominal imaging. It also has unique requirements for protocol creation depending on the dual-energy scanning technique that is being utilized. It also generates several new types of images which can increase the complexity of image creation and image interpretation. The purpose of this article is to review, for rapid switching and dual-source dual-energy platforms, methods for creating dual-energy protocols, different approaches for efficiently creating dual-energy images, and an approach to navigating and using dual-energy images at the reading station all using the example of a pancreatic multiphasic protocol. It will also review the three most commonly used types of dual-energy images: "workhorse" 120kVp surrogate images (including blended polychromatic and 70 keV monochromatic), high contrast images (e.g., low energy monochromatic and iodine material decomposition images), and virtual unenhanced images. Recent developments, such as the ability to create automatically on the scanner the most common dual-energy images types, namely new "Mono+" images for the DSDECT (dual-source dual-energy CT) platform will also be addressed. Finally, an approach to image interpretation using automated "hanging protocols" will also be covered. Successful dual-energy implementation in a high volume practice requires careful attention to each of these steps of scanning, image creation, and image interpretation.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Tamm EP, Le O, Liu X, et al. "How to" incorporate dual-energy imaging into a high volume abdominal imaging practice. Abdom Radiol (NY). 2017. PMID: 28070657. doi:10.1007/s00261-016-1035-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。