在尸体模型中优化超声探头位置以确认气管插管
本研究在5具尸体上由1名操作者插管,于甲状软骨、环状软骨和胸骨上窝三个水平放置超声探头,共30次插管,由2名评估者对图像评分。结果显示胸骨上窝水平对气管插管的显示率为100%,中位评分3分(明显运动),优于环状软骨水平(70%,中位2分)和甲状软骨水平(40%,中位1分)。
要点
- 胸骨上窝水平超声确认气管插管的显示率达100%,中位评分3分(明显运动)。
- 环状软骨水平显示率为70%,中位评分2分(清晰运动)。
- 甲状软骨水平显示率仅40%,中位评分1分(细微运动)。
核心结论
- 在尸体模型上比较上气道三个水平的超声确认气管插管效果,胸骨上窝水平的显示效果最优,100%插管被检出且评分最佳。
研究设计与样本
- 尸体模型研究,5具尸体,1名操作者插管,2名评估者评分,每个标本在每个水平共30次插管,共3个探头位置。
关键影像表现/征象
- 甲状软骨水平超声下气管插管表现为细微运动,中位评分1分。
- 环状软骨水平超声下表现为清晰运动,中位评分2分。
- 胸骨上窝水平超声下表现为明显运动,中位评分3分,全部插管均可见。
诊断标准与关键数值
- 视觉评分标准:1分(细微运动),2分(清晰运动),3分(明显运动)。
- 甲状软骨水平气管插管检出率40%,中位评分1分。
- 环状软骨水平气管插管检出率70%,中位评分2分。
- 胸骨上窝水平气管插管检出率100%,中位评分3分。
临床应用与阅片要点
- 在尸体模型中,胸骨上窝水平可获得最佳的超声图像用于确认气管插管位置。
- 甲状软骨水平图像质量较差,插管检出率低,可能不是理想的确认位置。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Sonography has been suggested as a possible means of endotracheal tube (ETT) placement confirmation. However, optimum ultrasound transducer placement has not been established. Using a cadaveric model, ETT placement by the sonographic appearance at the thyroid cartilage, cricoid cartilage, and suprasternal notch in the upper airway was assessed to determine which ultrasound transducer placement offered the most optimal images for ETT confirmation in the airway.
METHODS: One provider intubated 5 cadavers, with the ultrasound transducer at each of the 3 levels, for a total of 30 intubations per specimen, while 2 providers assigned a visual score of 1 (subtle), 2 (clear), or 3 (pronounced) to each sonogram of the ETT in the airway.
RESULTS: At the level of the thyroid cartilage, tracheal intubation was detected at a rate of 40%, with a median visualization scale of 1 (subtle movement). At the level of the cricoid cartilage, the visualization scale improved to a median of 2 (clear movement), with a 70% intubation detection rate. At the level of the suprasternal notch, 100% of the tracheal intubations were visualized on sonography, with a median score of 3 (pronounced movement).
CONCLUSIONS: In comparing sonographic detection of ETT placement at 3 levels of the upper airway in a cadaveric model, our results clearly indicate that visualization was superior at the level of the suprasternal notch, with 100% of intubations detected with the best visualization scores.
引用
- Lonchena T, So S, Ibinson J, et al. Optimization of Ultrasound Transducer Positioning for Endotracheal Tube Placement Confirmation in Cadaveric Model. J Ultrasound Med. 2017. PMID: 28072483. doi:10.7863/ultra.16.02010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。