基于光栅的相位对比CT离体评估冠状动脉粥样硬化斑块:与光学相干断层扫描的对照研究
在离体环境下,对5个心脏标本的15条人冠状动脉行基于光栅的相位对比CT(gb-PCCT)检查,并以光学相干断层扫描(OCT)和病理组织学为参照,评估gb-PCCT对斑块特征和血管径线的诊断准确性。共241个横断面纳入分析,gb-PCCT检测各斑块成分的敏感度≥0.95、特异度≥0.94,优于OCT,作者认为该技术可能作为实验环境下无创性先进斑块表征的辅助手段。
要点
- gb-PCCT检测纤维斑块、钙化斑块和脂质富集斑块的敏感度≥0.95、特异度≥0.94,诊断准确性优秀。
- gb-PCCT定量测值显著高于OCT(P<0.001),但与组织病理学强相关(Pearson r≥0.85)。
- OCT检测斑块成分的敏感度≥0.73、特异度≥0.66,Bland-Altman分析显示OCT与病理的均值差更小。
核心结论
- 在离体环境下,gb-PCCT在评估冠状动脉粥样硬化斑块特征和血管径线方面与OCT和病理组织学对照结果优秀,该技术可能作为实验环境下无创性先进斑块表征的辅助手段。
研究设计与样本
- 离体研究,5个心脏标本共15条人冠状动脉,采用实验性gb-PCCT装置(旋转钼阳极X线管、Talbot-Lau光栅干涉仪和单光子计数探测器)成像,随后行OCT和病理组织学处理;以病理组织学为参考标准,由2名独立观察者盲法阅片。
关键影像表现/征象
- 共评估286个横断面,241个对应横断面纳入统计分析。
- 基于病理组织学,228/241(94.6%)个横断面被分类为纤维性、钙化性或脂质富集斑块。
- gb-PCCT定量测值显著高于OCT(P<0.001),与病理组织学强相关(Pearson r≥0.85),OCT与病理组织学Pearson r≥0.61。
- Bland-Altman分析显示OCT与病理组织学的平均差异小于gb-PCCT与病理组织学;一致性界限在管腔面积方面gb-PCCT更窄,在斑块面积方面OCT更窄,在血管面积方面两者相当。
诊断标准与关键数值
- 以病理组织学为参考标准,gb-PCCT检测所有斑块成分(脂质富集、钙化、纤维性)的敏感度≥0.95、特异度≥0.94。
- OCT检测斑块成分的敏感度≥0.73、特异度≥0.66。
临床应用与阅片要点
- 作者认为gb-PCCT技术可能作为实验环境下无创性先进斑块表征的辅助手段。
局限性
- 本文为离体研究,作者结论中明确限定于实验环境(ex vivo setting / experimental setting)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to determine the diagnostic accuracy of grating-based phase-contrast computed tomography (gb-PCCT) to classify and quantify coronary vessel characteristics in comparison with optical coherence tomography (OCT) and histopathology in an ex vivo setting.
MATERIALS AND METHODS: After excision from 5 heart specimens, 15 human coronary arteries underwent gb-PCCT examination using an experimental imaging setup consisting of a rotating molybdenum anode x-ray tube, a Talbot-Lau grating interferometer, and a single photon counting detector. Subsequently, all vessels were imaged by OCT and histopathologically processed. Optical coherence tomography, gb-PCCT, and histopathology images were manually matched using anatomical landmarks. Optical coherence tomography and gb-PCCT were reviewed by 2 independent observers blinded to histopathology. Vessel, lumen, and plaque area were measured, and plaque characteristics (lipid rich, calcified, and fibrous) were determined for each section. Measures of diagnostic accuracy were derived, applying histopathology as the standard of reference.
RESULTS: Of a total of 286 assessed cross sections, 241 corresponding sections were included in the statistical analysis. Quantitative measures derived from gb-PCCT were significantly higher than from OCT (P < 0.001) and were strongly correlated with histopathology (Pearson r ≥0.85 for gb-PCCT and ≥0.61 for OCT, respectively). Results of Bland-Altman analysis demonstrated smaller mean differences between OCT and histopathology than for gb-PCCT and histopathology. Limits of agreement were narrower for gb-PCCT with regard to lumen area, for OCT with regard to plaque area, and were comparable with regard to vessel area. Based on histopathology, 228/241 (94.6%) sections were classified as fibrous, calcified, or lipid rich. The diagnostic accuracy of gb-PCCT was excellent for the detection of all plaque components (sensitivity, ≥0.95; specificity, ≥0.94), whereas the results for OCT showed sensitivities of ≥0.73 and specificities of ≥0.66.
CONCLUSIONS: In this ex vivo setting, gb-PCCT provides excellent results in the assessment of coronary atherosclerotic plaque characteristics and vessel dimensions in comparison to OCT and histopathology. Thus, the technique may serve as adjunct nondestructive modality for advanced plaque characterization in an experimental setting.
引用
- Habbel C, Hetterich H, Willner M, et al. Ex Vivo Assessment of Coronary Atherosclerotic Plaque by Grating-Based Phase-Contrast Computed Tomography: Correlation With Optical Coherence Tomography. Invest Radiol. 2017. PMID: 28079701. doi:10.1097/RLI.0000000000000346
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。