迭代模型重建可降低冠状动脉CT血管成像中的钙化斑块体积

Iterative model reconstruction reduces calcified plaque volume in coronary CT angiography.
PubMed 文献 · Eur J Radiol · 2016-12-14

研究对52例接受256层冠状动脉CTA的患者原始数据分别用IMR、HIR和FBP重建,评估图像质量并定量钙化及部分钙化斑块体积。结果显示IMR较HIR和FBP显著改善图像质量并降低钙化斑块体积,高衰减非钙化体积也低于FBP和HIR。

要点

  • IMR较HIR和FBP显著改善冠状动脉CTA主观图像质量和对比噪声比。
  • IMR重建的钙化斑块体积低于HIR和FBP,高衰减非钙化体积也低于两者。
  • 中等和低衰减非钙化体积在三种重建算法间无显著差异。

核心结论

  • IMR改善冠状动脉CTA图像质量并降低钙化斑块体积。

研究设计与样本

  • 对52例接受256层冠状动脉CTA患者的原始数据进行IMR、HIR和FBP三种重建,评估定性、定量图像质量并用自动软件定量钙化和部分钙化斑块体积。

诊断标准与关键数值

  • 对比噪声比:IMR 51.0(43.5-59.9)vs HIR 20.3(16.2-25.9)vs FBP 14.0(11.2-17.7),IMR较两者均升高,p<0.01。
  • 总斑块体积:IMR 121.7(79.3-168.4)最低,HIR 138.7(90.6-191.7),FBP 147.0(100.7-183.6)最高。
  • 钙化体积(>130 HU):IMR 105.9(62.1-144.6)vs HIR 110.2(63.8-166.6)vs FBP 115.9(81.7-164.2),IMR较两者降低,p<0.05。
  • 高衰减非钙化体积(90-129 HU):FBP与HIR相似(p=0.81),IMR低于两者(p<0.05)。
  • 中等衰减(30-89 HU)和低衰减(<30 HU)非钙化体积三种重建间无显著差异(p=0.22和p=0.67)。

临床应用与阅片要点

  • IMR可改善冠状动脉CTA图像质量并降低钙化斑块体积,阅片和定量斑块时需注意重建算法对钙化体积的影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the impact of iterative model reconstruction (IMR) on calcified plaque quantification as compared to filtered back projection reconstruction (FBP) and hybrid iterative reconstruction (HIR) in coronary computed tomography angiography (CTA).

METHODS: Raw image data of 52 patients who underwent 256-slice CTA were reconstructed with IMR, HIR and FBP. We evaluated qualitative, quantitative image quality parameters and quantified calcified and partially calcified plaque volumes using automated software.

RESULTS: Overall qualitative image quality significantly improved with HIR as compared to FBP, and further improved with IMR (p<0.01 all). Contrast-to-noise ratios were improved with IMR, compared to HIR and FBP (51.0 [43.5-59.9], 20.3 [16.2-25.9] and 14.0 [11.2-17.7], respectively, all p<0.01) Overall plaque volumes were lowest with IMR and highest with FBP (121.7 [79.3-168.4], 138.7 [90.6-191.7], 147.0 [100.7-183.6]). Similarly, calcified volumes (>130 HU) were decreased with IMR as compared to HIR and FBP (105.9 [62.1-144.6], 110.2 [63.8-166.6], 115.9 [81.7-164.2], respectively, p<0.05 all). High-attenuation non-calcified volumes (90-129 HU) yielded similar values with FBP and HIR (p=0.81), however it was lower with IMR (p < 0.05 both). Intermediate- (30-89 HU) and low-attenuation (<30 HU) non-calcified volumes showed no significant difference (p=0.22 and p=0.67, respectively).

CONCLUSIONS: IMR improves image quality of coronary CTA and decreases calcified plaque volumes.

来源:Eur J Radiol,查看原文。版权归原作者所有。